2015
DOI: 10.3390/s150818315
|View full text |Cite
|
Sign up to set email alerts
|

A Non-Contact Measurement System for the Range of Motion of the Hand

Abstract: An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-conta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
26
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 30 publications
(29 citation statements)
references
References 32 publications
(40 reference statements)
1
26
1
Order By: Relevance
“…Minimum and maximum active joint angles measured with Leap motion sensor and goniometer are compared using Bland-Altman plots and quantified by the mean difference and limits of agreement. Compared to previous similar studies [100], we avoided the use of Intraclass Correlation Coefficient (ICC) analysis. Our choice was motivated by the fact that there are no standard values for acceptable reliability using ICC [107] and that we had low variability in maximum flexion and extension angles between our participants, which disables the use of correlational analysis.…”
Section: Statistical Analysesmentioning
confidence: 99%
See 3 more Smart Citations
“…Minimum and maximum active joint angles measured with Leap motion sensor and goniometer are compared using Bland-Altman plots and quantified by the mean difference and limits of agreement. Compared to previous similar studies [100], we avoided the use of Intraclass Correlation Coefficient (ICC) analysis. Our choice was motivated by the fact that there are no standard values for acceptable reliability using ICC [107] and that we had low variability in maximum flexion and extension angles between our participants, which disables the use of correlational analysis.…”
Section: Statistical Analysesmentioning
confidence: 99%
“…However, goniometry is the current clinical standard, and there is a plethora of studies related to measurements, protocols and different goniometers . Moreover, comparable studies evaluated new and existing sensors and measurement protocols against the goniometer, reporting promising results and significant reduction in measurement time, yet asking for further improvements in measurements protocols [100], [103], [109].…”
Section: Rationalementioning
confidence: 99%
See 2 more Smart Citations
“…The Creative Senz3D device (see provides additional information about the hand location, but not skeletal information. HMI applications using this sensor include rehabilitation solutions as the one presented in [37], which measures the active range of the hand motion. Other rehabilitation solution introduces a system to improve the movement of the upper extremity [38].…”
Section: State Of the Art 31 Introductionmentioning
confidence: 99%