2013
DOI: 10.1088/1674-1137/37/6/066002
|View full text |Cite
|
Sign up to set email alerts
|

A normal-pressure MWPC for beam diagnostics at RIBLL2

Abstract: A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, which has a sensitive area of 80 mm×80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and without using protection wires. The detector has been tested with a 55 Fe X-ray source and a 200 MeV/u 12 C beam from CSRm. A position resolution better than 250 µm along the anode wires and a detection efficiency higher than 90% have been achieved.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…The diagnostic detector is needed to ensure that the beam has an ideal focus on the focal planes. Normally, the Parallel Plate Avalanche Counter (PPAC) [8] and the Multi-Wire Proportional Chamber (MWPC) [9] are placed at the focal planes as the diagnostic detector, which could provide the spatial resolution as hundreds of µm. In our study, a MAPS based diagnostic detector is expected to provide the spatial resolution of ∼ 10 µm for beam tuning in high vacuum condition.…”
Section: Jinst 14 C04007mentioning
confidence: 99%
“…The diagnostic detector is needed to ensure that the beam has an ideal focus on the focal planes. Normally, the Parallel Plate Avalanche Counter (PPAC) [8] and the Multi-Wire Proportional Chamber (MWPC) [9] are placed at the focal planes as the diagnostic detector, which could provide the spatial resolution as hundreds of µm. In our study, a MAPS based diagnostic detector is expected to provide the spatial resolution of ∼ 10 µm for beam tuning in high vacuum condition.…”
Section: Jinst 14 C04007mentioning
confidence: 99%
“…Returning now to Chinese, Miyagawa (2013) and Takahashi (2014) argue that the impossibility of subject AE in the language falls into place if it possesses abstract -feature agreement associated with the subject position. The hypothesis that Chinese possesses subject agreement was first argued for by Miyagawa (2010) based on the so-called blocking effect on ziji ‘self’ (Tang 1985, 1989). Consider examples (15)–(16).…”
Section: Argument Ellipsis In Japanese and Chinese And The Anti-agreementioning
confidence: 99%