2020
DOI: 10.1213/ane.0000000000004379
|View full text |Cite
|
Sign up to set email alerts
|

A Novel 3-Dimensional Approach for the Echocardiographic Evaluation of Mitral Valve Area After Repair for Degenerative Disease

Abstract: BACKGROUND: Currently available 2-dimensional (2D) echocardiographic methods for accurately assessing the mitral valve orifice area (MVA) after mitral valve repair (MVr) are limited due to its complex 3-dimensional (3D) geometry. We compared repaired MVAs obtained with commonly used 2D and 3D echocardiographic methods to a 3D orifice area (3DOA), which is a novel echocardiographic measurement and independent of geometric assumptions. METHODS: Intraopera… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 24 publications
0
3
0
Order By: Relevance
“…3D-TEE has been widely used for device sizing in LAA interventional procedures; however, the difference in the sizing accuracy of the 3DP and 3DV measurements has not yet been investigated. Previous studies have shown that the novel 3DP technique, which has improved accuracy, still uses a 2D plane acquired from the 3D data set for the structures, while the 3DV measurement enables the comprehensive identification of the complex asymmetric 3D borderline and non-planarity of the structures ( 28 , 29 ). In addition, the 3DV measurement measures the anatomic structure independently to patient hemodynamic variability ( 29 ).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…3D-TEE has been widely used for device sizing in LAA interventional procedures; however, the difference in the sizing accuracy of the 3DP and 3DV measurements has not yet been investigated. Previous studies have shown that the novel 3DP technique, which has improved accuracy, still uses a 2D plane acquired from the 3D data set for the structures, while the 3DV measurement enables the comprehensive identification of the complex asymmetric 3D borderline and non-planarity of the structures ( 28 , 29 ). In addition, the 3DV measurement measures the anatomic structure independently to patient hemodynamic variability ( 29 ).…”
Section: Discussionmentioning
confidence: 99%
“…Previous studies have shown that the novel 3DP technique, which has improved accuracy, still uses a 2D plane acquired from the 3D data set for the structures, while the 3DV measurement enables the comprehensive identification of the complex asymmetric 3D borderline and non-planarity of the structures ( 28 , 29 ). In addition, the 3DV measurement measures the anatomic structure independently to patient hemodynamic variability ( 29 ). In this study, we found that the 3DV measurement was more accurate in sizing the LAA clip device than the 3DP measurement.…”
Section: Discussionmentioning
confidence: 99%
“… 45 Although a mean gradient of less than 5 mmHg across the valve is characteristic of an adequate repair, 19 Riegel et al pointed out that higher mean gradients up to 7 mmHg immediately post-CPB might be present in situations of increased Left Atrial Pressure (LAP), namely high cardiac output, tachycardia and Atrial Fibrillation (AFib), and this may not cause clinical postoperative MS that needs to be addressed surgicaly. 46 Three observational studies attempted to compare different methods, and none of them showed strong evidence of a superior method 42 , 47 , 48 ( Table 1 ).…”
Section: Discussionmentioning
confidence: 99%