2015
DOI: 10.1016/j.chroma.2015.04.043
|View full text |Cite
|
Sign up to set email alerts
|

A novel 9×9 map-based solvent selection strategy for targeted counter-current chromatography isolation of natural products

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
24
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 48 publications
(24 citation statements)
references
References 44 publications
0
24
0
Order By: Relevance
“…Some studies were performed using FR purchased from the Pharmazeutische Biologie at the Universit€ at Bonn. In addition, FR was also isolated from the roots of Ardisia crenata sims using the targeted counter-current chromatography method with minor modifications (34,35). In brief, the dry powder of the roots of Ardisia crenata sims was first extracted with 95% ethanol, then the ethanol extract was partitioned by n-butanol-water.…”
Section: Fr900359mentioning
confidence: 99%
See 1 more Smart Citation
“…Some studies were performed using FR purchased from the Pharmazeutische Biologie at the Universit€ at Bonn. In addition, FR was also isolated from the roots of Ardisia crenata sims using the targeted counter-current chromatography method with minor modifications (34,35). In brief, the dry powder of the roots of Ardisia crenata sims was first extracted with 95% ethanol, then the ethanol extract was partitioned by n-butanol-water.…”
Section: Fr900359mentioning
confidence: 99%
“…A positive ESI-MS spectra showed the characteristic molecular ions at m/z 1002.27 [MþH] þ and 1024. 35 [MþNa] þ implying its molecular formula (C 49 H 75 N 7 O 15 ). 1 H NMR and 13 C NMR data were in close agreement with previous data (29).…”
Section: Fr900359mentioning
confidence: 99%
“…Choosing a suitable solvent system is an extremely important step for the separation of compounds by CCC, especially in the case of complex mixtures, such as plant extracts 8,27 . Literature reports n-hexane-ethyl acetatemethanol-water (HEMWat) [28][29][30][31]25 solvent system as the most suitable for isolation of flavonoid compounds.…”
Section: Resultsmentioning
confidence: 99%
“…And then when the proportion was 8:2:8:2, peak 1 had a suitable K value 1.54 (0.4 < K < 2.5) . In addition, this system has short settling time and is suitable to achieve high retention of stationary phase in CCC separation . So the solvent system (HEMWat, 8:2:8:2, v/v) was selected for the separation of peak 1.…”
Section: Resultsmentioning
confidence: 99%