2015
DOI: 10.1016/j.chroma.2015.07.048
|View full text |Cite
|
Sign up to set email alerts
|

A novel approach to the simultaneous extraction and non-targeted analysis of the small molecules metabolome and lipidome using 96-well solid phase extraction plates with column-switching technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
18
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(18 citation statements)
references
References 20 publications
0
18
0
Order By: Relevance
“…A wide range of applications of this technique includes analysis of low‐molecular mass pharmaceuticals in clinical samples; detection of toxicological substances, illicit and medicinal drugs and their metabolites in human blood and urine; and quantification of natural biologically active compounds . There are few reports on the peptides extraction from biological matrixes by microelution plates, nevertheless it was proved to be useful for proteomic studies and pharmaceutical profiling of peptide drug …”
Section: Introductionmentioning
confidence: 99%
“…A wide range of applications of this technique includes analysis of low‐molecular mass pharmaceuticals in clinical samples; detection of toxicological substances, illicit and medicinal drugs and their metabolites in human blood and urine; and quantification of natural biologically active compounds . There are few reports on the peptides extraction from biological matrixes by microelution plates, nevertheless it was proved to be useful for proteomic studies and pharmaceutical profiling of peptide drug …”
Section: Introductionmentioning
confidence: 99%
“…These observations may be due to the larger surface area (230 m 2 /g) of the of the HSS‐T3 particles as compared with the others (185 m 2 /g for BEH and CSH, and 225 m 2 /g for Ascentis Express), which enables faster interactions of the analytes with the stationary phase, resulting in better retentivity (Ali et al, ; Wyndham et al, ). Additionally, the T3‐endcapping and lower ligand density of this column has been shown to perform well with low molecular weight, polar analytes (Gros et al, ; Li et al, ). The HSS‐T3 column was used in subsequent analyses.…”
Section: Resultsmentioning
confidence: 99%
“…C8 and C18 cartridges have been used to isolate cerebrosides, gangliosides, eicosanoids, steroid hormones and FAs from polar matrixes in biofluid samples [26,[29][30][31]. 96-well SPE plates enable pretreatment of 96 samples at once, which enables improved automation, throughput and parallel mode of lipid extractions [32,33]. The development of automated SPE that is coupled online with LC largely simplifies lipid extraction procedures [34][35][36].…”
Section: Universal Extraction Methodsmentioning
confidence: 99%