2013
DOI: 10.1007/s12283-013-0146-7
|View full text |Cite
|
Sign up to set email alerts
|

A novel comparison between standard and new testing procedures to assess shock absorbency of third generation artificial turfs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 21 publications
0
8
0
Order By: Relevance
“…The average (±SD) peak force magnitude produced by this test on the most standard type of 3-g turf with sand/rubber four-layered infill of 35 mm thickness was 12.30 ± 0.24 kN, which was within the range of those readings observed in human severe landings (11.01–13.86 kN). 17 The rig consisted of an inverse steel pendulum system with a ball-bearing axis. In this test, the impact head was gently released by hand from the pendulum’s topmost position (688 mm height), with its downward motion controlled by gravity.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The average (±SD) peak force magnitude produced by this test on the most standard type of 3-g turf with sand/rubber four-layered infill of 35 mm thickness was 12.30 ± 0.24 kN, which was within the range of those readings observed in human severe landings (11.01–13.86 kN). 17 The rig consisted of an inverse steel pendulum system with a ball-bearing axis. In this test, the impact head was gently released by hand from the pendulum’s topmost position (688 mm height), with its downward motion controlled by gravity.…”
Section: Methodsmentioning
confidence: 99%
“…A high-load testing rig 17,18 was used ( Figure 1). Of the many physical parameters that could have been addressed, the test was designed to reproduce peak magnitudes during severe human landing conditions that likely occur during a football match.…”
Section: Testing Apparatusmentioning
confidence: 99%
See 2 more Smart Citations
“…Researchers have sought to address some of these concerns through creation of their own devices with an increased emphasis on biofidelity [19][20][21][22][23][24][25]. Whilst these devices have increased validity in terms of the player-surface interaction mechanics, little research has been conducted to assess whether the resulting measurements relate to players perceptions of the surfaces.…”
Section: Introductionmentioning
confidence: 99%