2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) 2010
DOI: 10.1109/apec.2010.5433643
|View full text |Cite
|
Sign up to set email alerts
|

A novel control method for unified power quality conditioner (UPQC) under non-ideal mains voltage and unbalanced load conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
30
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(30 citation statements)
references
References 11 publications
0
30
0
Order By: Relevance
“…Although, these two strategies are based on balanced three-phase systems, they can be used for single phase systems too [22,23]. In Some researches, these two control methods are combined to achieve a better performance for UPQC [24,25]. In most of these methods, a low pass filter (LPF) or a high pass filter (HPF) is used for separating the harmonic components from fundamental component.…”
Section: Introductionmentioning
confidence: 99%
“…Although, these two strategies are based on balanced three-phase systems, they can be used for single phase systems too [22,23]. In Some researches, these two control methods are combined to achieve a better performance for UPQC [24,25]. In most of these methods, a low pass filter (LPF) or a high pass filter (HPF) is used for separating the harmonic components from fundamental component.…”
Section: Introductionmentioning
confidence: 99%
“…However, in this structure six more IGBTs are needed compared with a three-phase half-bridge inverter, and this will increase the control complexity and the cost. In [6], the grid current and load voltage references in both dq and ab coordinates are calculated, and then hysteresis control is used to achieve grid current balance. However, the switching frequency of hysteresis control is not constant, and in [6] the design of appropriate LC filters is not considered.…”
Section: Introductionmentioning
confidence: 99%
“…In [6], the grid current and load voltage references in both dq and ab coordinates are calculated, and then hysteresis control is used to achieve grid current balance. However, the switching frequency of hysteresis control is not constant, and in [6] the design of appropriate LC filters is not considered. In [7], the grid currents are controlled as balanced sinusoidal currents in the positive and negative sequence double synchronous rotating coordinates under unbalanced loads.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Power systems, have many nonlinear loads, which significantly affect the quality of power supplies [11], [12].Power quality can be classified into three categories that is, voltage stability, continuity of supplying power, and voltage. Comprehensive review of compensating type custom power devices, issues of power quality [13][14][15][16] The control strategy is for series converter along with the DC link control.…”
mentioning