A Novel Control Strategy for Shunt Active Power Filter under Nonlinear and Unbalanced Three Phase Load Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…It can be seen that the research of [1] and [2] are mainly focused on choosing the active phase in the network. This mainly ensures continuity of power supply but does not sufficiently eliminate voltage asymmetry.…”
Section: Experimental Researchmentioning
confidence: 99%
See 1 more Smart Citation
“…It can be seen that the research of [1] and [2] are mainly focused on choosing the active phase in the network. This mainly ensures continuity of power supply but does not sufficiently eliminate voltage asymmetry.…”
Section: Experimental Researchmentioning
confidence: 99%
“…One of the challenges faced by power distribution networks is voltage asymmetry, which occurs when there are imbalances in voltage levels across different phases. Voltage asymmetry can lead to several issues, including increased energy losses, reduced equipment lifespan, and compromised power quality [1][2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…Fig. 1-b is a simple display of shunt active power filters, as it is shown APF is compensating the nonlinear load current by injecting the same nonlinear current that load absorbs from the grid, so that the grid current will be sinusoidal [66,67] Ongoing researches in this field are concentrated over novel control methods of shunt active power filters and also new applications for shunt APFs [68][69][70][71][72][73][74][75][76][77][78][79][80]. More detailed analysis of main topologies of shunt active power filters is done in [81].…”
Section: Shunt Active Power Filtermentioning
confidence: 99%
“…In Gowtham and shobha's paper, they have used a PI controller whose proportional and integral constants are being optimised using genetic and PSO algorithm [21]. In the same control strategy, PI controller was being replaced by fuzzy logic controller to improve the performance of system in a paper by Shuai Hao et al [22]. In a paper by Yu Wang et al, the study investigates the inherent influence of a DC-link voltage controller on both DC-link voltage control and the compensation performance of a three-phase, four-wire SAPF [23].…”
Section: B DC Link Pi Control Theorymentioning
confidence: 99%