A Novel Fault-Location Algorithm for AC Parallel Autotransformer Feeding System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 10 publications
0
11
0
Order By: Relevance
“…Moreover, the assessment of the contact electro-erosion of the circuit breakers from the power supply installations in the railway traction is made by counting the number of disconnections (in normal or faulty regime) and the disconnected real current value is not taken into account. This assessment of the contact electro-erosion is done according to the technical data sheets and/or operating instructions [ 13 ]. Finally, this leads to maintenance activities at inadequate times regarding the electrical wear of the contacts of those circuit breakers.…”
Section: Methods and Functional Scheme Of The Fault Location System From Power Supply System Of Railway Infrastructurementioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, the assessment of the contact electro-erosion of the circuit breakers from the power supply installations in the railway traction is made by counting the number of disconnections (in normal or faulty regime) and the disconnected real current value is not taken into account. This assessment of the contact electro-erosion is done according to the technical data sheets and/or operating instructions [ 13 ]. Finally, this leads to maintenance activities at inadequate times regarding the electrical wear of the contacts of those circuit breakers.…”
Section: Methods and Functional Scheme Of The Fault Location System From Power Supply System Of Railway Infrastructurementioning
confidence: 99%
“…In this sense, some research papers describe some new methods to measure the line impedance in order to improve distance protection relays, in the sense of quick location of a fault, for improving the continuity and reliability of the railway infrastructure [ 13 , 14 , 15 , 16 ]. Furthermore, Cho et al [ 13 ] present a fault locator used to detect the fault location with good accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…Lin et al [13] combined the AT neutral current ratio method and the reactance method to realize fault location for the over-zone feeding operation condition in high-speed electrified railways. Considering the structure of Korean railway system, Cho et al [14] proposed a novel fault location method based on the relationship between AT neutral currents and branch currents, which improved the accuracy of fault location for Korean traction power supply system. Serrano et al [15] proposed a method of ground fault location based on currents of the ATs.…”
Section: Introductionmentioning
confidence: 99%
“…To compensate for the neutral currents circulating in adjacent autotransformers, a revision algorithm with the neutral current ratio method has been proposed [10]. Recently, methods derived from the neutral current ratio were also proposed in [11,12]. Many researchers have proposed to use of traveling wave methods for the fault location scheme of AC electric railway systems [13][14][15].…”
Section: Introductionmentioning
confidence: 99%