2015
DOI: 10.1016/j.aca.2014.12.037
|View full text |Cite
|
Sign up to set email alerts
|

A novel fourth-order calibration method based on alternating quinquelinear decomposition algorithm for processing high performance liquid chromatography–diode array detection– kinetic-pH data of naptalam hydrolysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
6
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(6 citation statements)
references
References 31 publications
0
6
0
Order By: Relevance
“…Results obtained by this approach have been shown to be equivalent to those obtained by other multilinear decomposition methods like PARAFAC and/or its extensions 617 18 . Other methods and applications have been proposed in the literature for the extension of the trilinear model to the quadrilinear and quinquelinear models in the analysis of kinetic‐pH data coupled to LC‐DAD 19 , spectrofluorimetric 2021 and luminescence 22 data. However, all these methods are based on the fulfillment of the model for all the components obtained in the decomposition.…”
Section: Introductionmentioning
confidence: 65%
“…Results obtained by this approach have been shown to be equivalent to those obtained by other multilinear decomposition methods like PARAFAC and/or its extensions 617 18 . Other methods and applications have been proposed in the literature for the extension of the trilinear model to the quadrilinear and quinquelinear models in the analysis of kinetic‐pH data coupled to LC‐DAD 19 , spectrofluorimetric 2021 and luminescence 22 data. However, all these methods are based on the fulfillment of the model for all the components obtained in the decomposition.…”
Section: Introductionmentioning
confidence: 65%
“…At present, two-way, three-way and higher-way kinetic measurements have been reported in the literature [39][40][41][42][43][44][45][46][47]. It is well known that processing the data as its original higher-way structure is better than unfolding it into array of lower dimensions.…”
Section: Introductionmentioning
confidence: 99%
“…Fortunately, the chemometrics second-order calibration method provides a good analytical strategy to conduct source apportionment of ambient particulate matter. It has the advantages of simplifying sample pretreatments, resolving overlapped chromatographic peaks and providing physicochemical information on components in an actual system because of its well-known "second-order advantage" [22][23][24].…”
Section: Introductionmentioning
confidence: 99%