2014
DOI: 10.1039/c4an01051e
|View full text |Cite
|
Sign up to set email alerts
|

A novel method for the identification of inorganic and organic gunshot residue particles of lead-free ammunitions from the hands of shooters using scanning laser ablation-ICPMS and Raman micro-spectroscopy

Abstract: A method based on scanning laser ablation and inductively coupled plasma-mass spectrometry (SLA-ICPMS) and Raman micro-spectroscopy for the detection and identification of compounds consistent with gunshot residue particles (GSR) has been developed. The method has been applied to the characterization of particles resulting from the discharge of firearms using lead-free ammunition. Modified tape lifts were used to collect the inorganic and organic residues from skin surfaces in a single sample. Using SLA-ICPMS,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
36
0
4

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 51 publications
(40 citation statements)
references
References 39 publications
0
36
0
4
Order By: Relevance
“…Hori dela eta, Abrego eta lankideek [76,77] tiro-partikulen zalantzarik gabeko identifikazioa egiteko LA-ICPMS teknikan oinarritutako metodoa garatu dute, laginaren aurretratamendurik behar ez duena eta analisi-denbora nabarmenki murrizten duena (66 min), eta horrela, SEM-EDX teknikak dituen desabantailak gainditu. Metodo horretan, tiro-aztarnen laginketarako karbonozko zinta itsaskorra erabiltzen da eta laserra gainazaletik Laser bidezko ablazioaren egungo egoera eta aplikazioak abiadura jakin batekin desplazatzen da, sigi-saga erako patroi bat jarraituz.…”
Section: Tiro-aztarnen Identifikazioaunclassified
“…Hori dela eta, Abrego eta lankideek [76,77] tiro-partikulen zalantzarik gabeko identifikazioa egiteko LA-ICPMS teknikan oinarritutako metodoa garatu dute, laginaren aurretratamendurik behar ez duena eta analisi-denbora nabarmenki murrizten duena (66 min), eta horrela, SEM-EDX teknikak dituen desabantailak gainditu. Metodo horretan, tiro-aztarnen laginketarako karbonozko zinta itsaskorra erabiltzen da eta laserra gainazaletik Laser bidezko ablazioaren egungo egoera eta aplikazioak abiadura jakin batekin desplazatzen da, sigi-saga erako patroi bat jarraituz.…”
Section: Tiro-aztarnen Identifikazioaunclassified
“…Behin laser bidezko metodoaren baliagarritasuna frogatuta, lau munizio berde desberdinen tiro-aztarnak analizatu dira, beruna ez duten hiru munizio eta metal astunik ez duen munizio bat [32]. Argitu beharra dago, munizio hauek beruna edo metal astunak ez dituztela esaten denean, metal astunak hasarazletik kendu direla esan nahi dela, eta askotan bala edota kartutxoetan metal astunak aurkitu daitezke.…”
Section: Tiro-aztarnen Identifikazioa Auzitegi-laborategien Erronkaunclassified
“…Partikula bereizgarri horiez gain, munizio berde hauetan bestelako konposizioa duten partikula batzuk ere aurkitu dira, Sb-Ba, Cu-Zn, Al-Ti eta Al-Sr-Zr, besteak beste. Halere, ezinezkoa da munizio berezi hauetan bereizgarria den partikula mota bat definitzea, eta munizio bakoitza kasuz kasu analizatuz, partikulen konposizio bereizgarri bat definitu beharko litzateke [32].…”
Section: Tiro-aztarnen Identifikazioa Auzitegi-laborategien Erronkaunclassified
See 1 more Smart Citation
“…Solvent extraction has been employed for the extraction of OGSR compounds from smokeless (propellant) powders [8,10,11] and spent cartridges [46], as well as OGSR compounds collected on a swab or (modified) stub [12,53] and from vacuum collected samples [45]. Solvent extraction involves dissolving the sample by submerging the powder or object containing the OGSR sample in a solvent for a period of time.…”
Section: Solvent Extractionmentioning
confidence: 99%