1988
DOI: 10.1109/28.6109
|View full text |Cite
|
Sign up to set email alerts
|

A novel method of harmonic assessment generated by three-phase AC-DC converters under unbalanced supply conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

1999
1999
2019
2019

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(9 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…It is worthwhile underlining that by using proper voltage and current modulation functions it is possible to take into account also supply voltage unbalances [6], [18], [19] and distortion [20]. This is possible without particular difficulties when the unbalances and the distortion are superimposed by external causes.…”
Section: F Considerationsmentioning
confidence: 99%
“…It is worthwhile underlining that by using proper voltage and current modulation functions it is possible to take into account also supply voltage unbalances [6], [18], [19] and distortion [20]. This is possible without particular difficulties when the unbalances and the distortion are superimposed by external causes.…”
Section: F Considerationsmentioning
confidence: 99%
“…The latter case can be caused by overhead power transmission lines without transposition or faulty transmission lines, for example. Current converters operated in such unbalanced electrical systems will generally work asymmetrically, which introduces firstly the appearance of non-characteristic harmonics, which causes distortion levels, higher than those in a balanced operation [1,2]. As a high distortion level is always disadvantageous, a method to keep the distortions as low as possible is desirable.…”
Section: Introductionmentioning
confidence: 97%
“…Space-phasor network for conducting state T(1,2,3) According tofig. 2, when T(1,2,3)is finished, the next conducting state is T(2,3).…”
mentioning
confidence: 99%
“…A novel way of modeling the voltage unbalance by introducing a deviation voltage superimposed on balanced three-phase line voltages was established. Modeling of six pulse rectifier operating under balanced & unbalanced supply conditions has been discussed [9][10]. A time domain model for six pulse rectifier taking into account the system losses, supply impedances, and unbalanced voltage source was developed.…”
Section: Introductionmentioning
confidence: 99%