A novel methodology for effective short-circuit calculation in offshore wind power plants considering converter limitations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…Assuming that the stator voltage u s0 before the fault is rated, the active and reactive power depend on the setting of the working conditions before the network failure. The rotor flux ψ r is obtained from Equation (15) and the rotor flux ψ r is brought into Equation (12) to obtain the short circuit current i ' so at the initial moment of grid voltage drop.…”
Section: Short-circuit Current Calculation Methods Of Dfig Group At T...mentioning
confidence: 99%
See 1 more Smart Citation
“…Assuming that the stator voltage u s0 before the fault is rated, the active and reactive power depend on the setting of the working conditions before the network failure. The rotor flux ψ r is obtained from Equation (15) and the rotor flux ψ r is brought into Equation (12) to obtain the short circuit current i ' so at the initial moment of grid voltage drop.…”
Section: Short-circuit Current Calculation Methods Of Dfig Group At T...mentioning
confidence: 99%
“…In this case, the output short-circuit current of the DFIG is affected by the converter control characteristics [14]. Therefore, it is necessary to consider the low-voltage crossing control strategy and the control characteristics of the converter when calculating the short-circuit current [15].…”
Section: Introductionmentioning
confidence: 99%
“…Then, a set of systems of equations, SE, considering the inserted z out , is defined and solved. Potential existence of multiple equilibrium points is ignored in this paper and the solution function, which is defined in [32] for single-phase expression, returns the identified equilibrium points as a vector (u outx , u outy , i outx , i outy ). Each obtained solution is saved into the U-I characteristic array C eq .…”
Section: B Methodology To Obtain U-i Characteristicmentioning
confidence: 99%
“…In particular, the equivalent model of power converters, which involves a specific control mode and various potential current-saturation states, is included in the system formulation. Then, the system equilibrium point that satisfies all converters' operation limits can be identified by either going through all possible combinations of converters' current-saturation states [30], [31] or testing only selected combinations iteratively for a more efficient calculation [32], [33]. The previous studies are based on the formulation of the complete studied system.…”
Section: Nomenclaturementioning
confidence: 99%