2021
DOI: 10.1039/d0ra10676c
|View full text |Cite
|
Sign up to set email alerts
|

A novel molecularly imprinted electrochemiluminescence sensor based on cobalt nitride nanoarray electrode for the sensitive detection of bisphenol S

Abstract: Sensitive molecularly imprinted ECL sensor for the determination of BPS based on the CoN nanoarray electrode directly used as the ECL sensing platform was fabricated for the first time.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 46 publications
0
6
0
Order By: Relevance
“…Cheng et al developed molecularly imprinted chemiluminscence (MIECLS) sensors for the detection of bisphenol S (BPS) in drinking water. 116 BPS is often used as a substitute for bisphenol A (BPA) so plastics can be advertised as "BPA-free", but BPS has been found to be an environmental toxin that has disruptive effects to the endocrine system and is released into drinking water in commercial water bottles.…”
Section: Reviewmentioning
confidence: 99%
“…Cheng et al developed molecularly imprinted chemiluminscence (MIECLS) sensors for the detection of bisphenol S (BPS) in drinking water. 116 BPS is often used as a substitute for bisphenol A (BPA) so plastics can be advertised as "BPA-free", but BPS has been found to be an environmental toxin that has disruptive effects to the endocrine system and is released into drinking water in commercial water bottles.…”
Section: Reviewmentioning
confidence: 99%
“…Bisphenol A (2, 2-bis(4-hydroxyphenyl) propane, BPA) is a phenolic compound and an endocrine disrupting compound that shows estrogenic activity, and may have adverse effects on humans, wildlife, and reproductive systems [ 64 ]. A series of electrochemical biosensors based on porous carbon-based composite materials were developed for the detection of phenols, as shown in Table 1 .…”
Section: The Application Of Electrochemical Sensors and Biosensors Ba...mentioning
confidence: 99%
“…Compared to other methods, ECL has the advantages of a wide linear range, high sensitivity, good stability, low background, and fast response. ECL has been widely used in the fields of biological immunoassay, medical diagnosis, food and environmental monitoring, [10][11][12] etc. The ECL luminophore reagent directly affects the performance of the constructed ECL biosensor.…”
Section: Introductionmentioning
confidence: 99%