2019
DOI: 10.1109/tia.2019.2925785
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Orthogonal Current Decomposition Control for Grid-Connected Voltage Source Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 23 publications
0
15
0
Order By: Relevance
“…Notably, the load reactive power demand is also reduced considerably with the multifunctional PV inverter operation, which evident the UPF operation. Furthermore, the recorded values of THD's in grid currents are found to be well within the acceptable limit specified in IEEE draft 519‐2014 . It is worth mentioning that during the entire operation, an inverter absorbs an insignificant amount of active power to retain the DC‐bus voltage within the normal working limit, in addition, to diminish the switching losses incurred in the inverter circuit.…”
Section: Hardware Development and Experimental Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Notably, the load reactive power demand is also reduced considerably with the multifunctional PV inverter operation, which evident the UPF operation. Furthermore, the recorded values of THD's in grid currents are found to be well within the acceptable limit specified in IEEE draft 519‐2014 . It is worth mentioning that during the entire operation, an inverter absorbs an insignificant amount of active power to retain the DC‐bus voltage within the normal working limit, in addition, to diminish the switching losses incurred in the inverter circuit.…”
Section: Hardware Development and Experimental Resultsmentioning
confidence: 99%
“…It is worth mentioning that there is only a single point situated at a power curve, which typically represents the MPP point. The core idea of INC‐based MPP‐tracking control technique is that SPV power derivative with respect to its voltage dP SPV / dV SPV is yield to zero at MPP . The derivative of SPV power against its corresponding SPV voltage can be represented by (33).…”
Section: Description Of Grid‐connected Spv Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…But the shunt APF will maintain the desired dc‐link voltage. Therefore [7], the reference power to be extracted from the grid is then derived as, Pnormalref=PnormalLavg+Pl. Then, the balanced positive sequence reference grid input current (isabc) are calculated as isabc=v̂sabc+(truev̂fα+)2+(truev̂fβ+)2Pnormalref…”
Section: Control Algorithmmentioning
confidence: 99%
“…To alleviate this problem, recently, in [12], a newer fundamental decomposition-based control is devised. In this method, an orthogonal signal property is used to detect the fundamental component of the current.…”
Section: Introductionmentioning
confidence: 99%