A Novel Reclosing Algorithm Considering Turbine-Generator Shaft Torque

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…where X is the system state variables of the incremental form, and A is the state matrix of the system. The corresponding eigenvalue equation of the system is [8] |λI − A| = 0…”
Section: Eigenvalue Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…where X is the system state variables of the incremental form, and A is the state matrix of the system. The corresponding eigenvalue equation of the system is [8] |λI − A| = 0…”
Section: Eigenvalue Analysismentioning
confidence: 99%
“…The main function of the speed governing system of a modern large turbogenerator is to adjust the speed and load of the system. The state characteristic equations of the speed governing system at an operating point are established as follows [8].…”
Section: Turbine Speed Governing Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…By far, the EMT ripple properties in normal condition have been well studied by scholars [4,5]. Since the magnetic flux density (MFD), which is closely related to EMT, will be changed due to different faults, the EMT ripple characteristics will be also varied in different fault cases.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, the single‐phase reclosing scheme applied to a WPO line is simply adopted from the scheme used in conventional power transmission lines, which merely recloses the faulty phase after a fixed time (ie, dead time) without distinguishing between transient and permanent faults. Such “blind” reclosing may cause the wind farms and the relative power systems to reclose to a fault for another time, and stability and reliability of both connected wind farms and power systems will be seriously affected . Consequently, it is of great importance to propose adaptive single‐phase auto‐reclosing (ASPAR) schemes that can identify transient faults from the permanent ones and reclose a WPO line only after guaranteeing extinction of a transient fault.…”
Section: Introductionmentioning
confidence: 99%