A novel, remote-controlled suspension device for brain tissue PO2 measurements with multiwire surface electrodes

Abstract: A new device was developed for rapid assessment of PO2 values in viable tissue, such as the brain, using a multiwire surface electrode. The instrument utilizes a phonograph-like construction with weightless suspension of the electrode which thus minimizes surface pressure and allows for compensation of brain movements. The new and original component of the present device is the motor-driven, servo-controlled rotation of the PO2 electrode around its vertical axis. This enables PO2 measurements from precisely de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
14
0

Year Published

2000
2000
2015
2015

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 9 publications
2
14
0
Order By: Relevance
“…4. Thus, although the estimated concentration of brain extracellular O 2 is relatively low at approximately 50 mM (Nair et al, 1987;Murr et al, 1994), significant increases in its concentration did not affect the glucose current, supporting the O 2 interference analysis presented in Section 3.2.…”
Section: Oxygen-sensitivity Of Pt/ppd/gox Responses To Glucose In Vivosupporting
confidence: 68%
See 1 more Smart Citation
“…4. Thus, although the estimated concentration of brain extracellular O 2 is relatively low at approximately 50 mM (Nair et al, 1987;Murr et al, 1994), significant increases in its concentration did not affect the glucose current, supporting the O 2 interference analysis presented in Section 3.2.…”
Section: Oxygen-sensitivity Of Pt/ppd/gox Responses To Glucose In Vivosupporting
confidence: 68%
“…Although O 2 ECF levels farthest from blood brain capillaries can be as low as 5 mM (Siesjo, 1978), electrodes the size of CPEs and Pt/PPD/GOx sensors sample the average tissue ECF concentration, estimated at Â/50 mM (Nair et al, 1987;Murr et al, 1994). We therefore calculated the percentage O 2 interference in the glucose signals at 50 mM O 2 per micromolar change in O 2 concentration (S % ), i.e., the tangential slope of plots similar to those in Fig.…”
Section: Oxygen-sensitivity Of Pt/ppd/gox Responses To Glucose In Vitromentioning
confidence: 99%
“…The KmO 2 calculated from the fits averaged 2.6 ± 1.1 µM (n=4). This result shows that the sensor response is virtually insensitive to changes in O 2 above 10 µM, a value at the low end of the distribution of O 2 concentrations found in vivo (Murr et al, 1994;Nair et al, 1987).…”
Section: Oxygen Dependence Of Biosensor Responsementioning
confidence: 86%
“…Measurements of extracellular O 2 concentration in the neocortex and hippocampus have shown a broad distribution of O 2 basal levels around a mean of 35-50 µM but with a considerable number of observations at lower levels, down to 10 µM (Murr et al, 1994;Nair et al, 1987). The extracellular O 2 concentration is also dynamically regulated according to changes in metabolic demand imposed by neuronal activity (Lourenço et al, 2014;Masamoto and Tanishita, 2009).…”
Section: Introductionmentioning
confidence: 96%
“…The electrode consists of eight platinum wires and allows simultaneous monitoring of eight different tissue points by recording the pO 2 signals from a spheroid tissue volume of 12 mm in diameter. The employment of a micromanipulator [10] facilitates the gentle movement of the electrode in 8-10 0.5-mm steps permitting assessment of pO 2 at n = 64-80 local data points per animal and time point of investigation. The pO 2 values were registered from the striated skin muscle and classified into 5-mm ranges versus frequency of occurrence.…”
Section: Local Tissue Po 2 Measurementsmentioning
confidence: 99%