International Conference of Numerical Analysis and Applied Mathematics Icnaam 2019 2020
DOI: 10.1063/5.0026461
|View full text |Cite
|
Sign up to set email alerts
|

A numerical study for the assessment of air pollutant dispersion with chemical reactions from a thermal power plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…A theoretical simulation of the contaminant's distribution and chemical interactions in the atmosphere during fuel burning at Ekibastuz SDPP-1 has been presented. A real-life example of a thermal power plant was used to model the dispersion of NO, NO2, CO, and products NO2, HNO3, CO2 waiting for chemical interaction with oxygen (Ekibastuz SDPP -1) [19]. The effects of different emission scenarios on NOx, SO2, PM total, and CO concentrations were simulated using the AERMOD air quality model.…”
Section: Emission Studymentioning
confidence: 99%
“…A theoretical simulation of the contaminant's distribution and chemical interactions in the atmosphere during fuel burning at Ekibastuz SDPP-1 has been presented. A real-life example of a thermal power plant was used to model the dispersion of NO, NO2, CO, and products NO2, HNO3, CO2 waiting for chemical interaction with oxygen (Ekibastuz SDPP -1) [19]. The effects of different emission scenarios on NOx, SO2, PM total, and CO concentrations were simulated using the AERMOD air quality model.…”
Section: Emission Studymentioning
confidence: 99%
“…These turbulent models were described in detail in 67 – 70 . All simulations were performed using the SST k-ω turbulent model, as this model has proven to be reliable in indoor airflow modeling 71 76 .…”
Section: Mathematical Modelmentioning
confidence: 99%
“…All the model equations used for the simulation and description have been referred from peer-reviewed publications ( Spalart, 1997 , Menter, 1994 ; Menter and Kuntz, 2003; Jones and Launder, 1972 ). The SST k-ω model was used owing to its ability to demonstrate a precise depiction of the indoor airflow ( Stamou and Katsiris, 2006 , Zhang et al, 2009 , Hussain and Oosthuizen, 2012 , Hussain et al, 2012 ; Issakhov et al, 2021; Issakhov et al, 2020 ).…”
Section: Methodsmentioning
confidence: 99%