2015
DOI: 10.2208/journalofjsce.3.1_93
|View full text |Cite
|
Sign up to set email alerts
|

A Numerical Study on Multi-Chamber Oscillating Water Columns

Abstract: A two-dimensional frequency-domain numerical analysis on the primary conversion efficiency of multi-chamber Oscillating Water Columns (OWCs) is presented. The numerical model is developed by combining the hydrodynamics of the interaction between the wave and the OWC and the thermodynamics of the air chambers. The wave-induced force is calculated using the boundary element method based on the velocity potential theory. The air flow is studied using mass and energy conservation equations and an equation of state… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…The electric resistor is 3,040  constant. The basis thickness of the curtain wall is tc = 0.005 m and the curtain wall depth is 0.1 m. The length L of air chamber is 0.7 m. The outline design of air chamber was carried out in the simulations [13].…”
Section: Methodsmentioning
confidence: 99%
“…The electric resistor is 3,040  constant. The basis thickness of the curtain wall is tc = 0.005 m and the curtain wall depth is 0.1 m. The length L of air chamber is 0.7 m. The outline design of air chamber was carried out in the simulations [13].…”
Section: Methodsmentioning
confidence: 99%
“…The torque transducer (SS-005) and the electromagnetic rotation detector (MP-981) produced by ONO SOKKI Co. Ltd. (Yokohama, Japan) were located at the end of the turbine shaft. The basic chamber length is 0.7 m, the curtain wall depth is 0.1 m and the thickness of the curtain wall is 0.005 m. The schematic design of the air chamber was conducted in a series of numerical studies [20]. Figure 3 indicates the locations of the pressure gauge (AP-10S) and the wave height gauges (FW-H07 and UD320) made by the KEYENCE CORPORATION (Osaka, Japan) at the top of the air chamber.…”
Section: Experimental Apparatusmentioning
confidence: 99%
“…The torque transducer (SS-005) and the electromagnetic rotation detector (MP-981) produced by ONO SOKKI Co., Ltd. were located at the end of the turbine shaft. The air chamber length is 0.7 m, the curtain wall depth is 0.1 m and the thickness of the curtain wall is 0.005 m. The schematic design of the air chamber was conducted in a series of numerical studies [14]. Fig.…”
Section: Introductionmentioning
confidence: 99%