2018
DOI: 10.1109/jlt.2017.2784678
|View full text |Cite
|
Sign up to set email alerts
|

A Packaged Whispering Gallery Mode Strain Sensor Based on a Polymer-Wire Cylindrical Micro Resonator

Abstract: Abstract-We propose a whispering gallery mode (WGM) strain sensor formed by a polymer-wire cylindrical micro resonator for strain measurement applications. WGMs are generated by evanescently coupling light into the polymer-wire resonator from a silica fiber taper fabricated by the micro heater brushing technique. Accurate and repeatable measurements of a strains up to one free spectral range (FSR) shift of the WGMs (corresponding to 0.33 % of the polymer-wire elongation, 3250 μɛ) are demonstrated experimental… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 29 publications
(16 citation statements)
references
References 35 publications
0
16
0
Order By: Relevance
“…Figure 1 (c) is a schematic of a packaged triple-cylindrical resonator array. The robustness of the packaged system was confirmed by testing the device in the presence of strong vibrations by placing it on a mechanical vibration generator as explained in [20]. Figure 2 shows the photograph of an ICOMR formed by three cylindrical microresonators.…”
Section: Initial Feasibility Experimentsmentioning
confidence: 98%
See 2 more Smart Citations
“…Figure 1 (c) is a schematic of a packaged triple-cylindrical resonator array. The robustness of the packaged system was confirmed by testing the device in the presence of strong vibrations by placing it on a mechanical vibration generator as explained in [20]. Figure 2 shows the photograph of an ICOMR formed by three cylindrical microresonators.…”
Section: Initial Feasibility Experimentsmentioning
confidence: 98%
“…The PDMS coated silica micro-resonator and the tapered POF micro-resonator served for temperature and strain measurements respectively. PDMS material was chosen for the coating of the silica micro-cylinder due to its low attenuation loss, good chemical stability and large thermo-optic coefficient [21], while a POF micro-cylinder was chosen for strain sensing because of its large elastic modulus compared to silica fibers [20,22,23]. The PDMS coating was prepared as a solution with a base to curing agent ratio of 5:1.…”
Section: Multi-parameter Sensing Using Icomrsmentioning
confidence: 99%
See 1 more Smart Citation
“…The results showed that the axial strain of the device can reach 3250 με and the sensitivity of axial tension strain was respectively −0.68 pm με −1 (no package) and −0.58 pm με −1 (package). In addition, external vibration had little effect on the performance of the sensor …”
Section: Structure and Application Of Wgmrsmentioning
confidence: 99%
“…With the continuous improvement of WGMRs in optical sensing, many novel geometric structures have appeared in recent years, such as: microdisk, [17,[116][117][118][119][120][121][122][123][124][125] microbubble, [126][127][128][129][130][131][132] microbottle, [133][134][135][136][137][138][139][140][141][142][143][144][145][146][147] microtube, [148][149][150][151][152][153][154][155][156][157][158][159][160] microcylinder, [161][162][163] etc. These new resonators are widely used in the field of phy...…”
Section: Preparation and Application Of Other Types Of Resonatorsmentioning
confidence: 99%