2020
DOI: 10.3390/diagnostics11010006
|View full text |Cite
|
Sign up to set email alerts
|

A Paper-Based Analytical Device for Analysis of Paraquat in Urine and Its Validation with Optical-Based Approaches

Abstract: Paraquat is a highly toxic herbicide. Paraquat poisoning is often fatal and is an important public health threat in many places. The quick identification and timely initiation of treatment based on timely analysis of the paraquat concentration in urine/serum could improve the prognosis for patients. However, current paraquat concentration measurements are time-consuming and difficult to implement due to the expensive and bulky equipment required. To address these practical challenges, paper-based devices have … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…With this method, the LOD and LOQ of PQ were 3.01 μg/mL and 10.02 μg/mL, respectively. The PAD was comparable to that of other conventional colorimetric methods, and the urine paraquat concentration detection was non-invasive and had prognostic significance [ 85 ].…”
Section: Methodsmentioning
confidence: 94%
See 1 more Smart Citation
“…With this method, the LOD and LOQ of PQ were 3.01 μg/mL and 10.02 μg/mL, respectively. The PAD was comparable to that of other conventional colorimetric methods, and the urine paraquat concentration detection was non-invasive and had prognostic significance [ 85 ].…”
Section: Methodsmentioning
confidence: 94%
“…PQ reacts with sodium dithionite to form a blue radical ion. Some researchers have also developed two-in-one PADs that simultaneously determine serum paraquat and creatinine levels to quickly detect paraquat poisoning and assess renal prognosis [ 85 ]. With this method, the LOD and LOQ of PQ were 3.01 μg/mL and 10.02 μg/mL, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Here, we proposed the use of a rapid IL-6 test strip which contains a lateral flow immunoassay (LFA)-based kit accompanied by a handheld optical reader that, in combination, is well suited for recognizing acute respiratory failure among COVID-19 patients. The spectrum-based optical reader is a palm-size portable chip-based spectrometric device ( Hung et al, 2021 ), based on innovative micro-grating technology applied for biomedical spectral analysis ( Kita et al, 2018 ; Wang et al, 2020a ). In this study, we aimed to use a combination of an LFA technique-based IL-6 test strip and a sensitivity-enhanced spectrometric reader for early recognition of COVID-19 patients who may develop respiratory failure.…”
Section: Introductionmentioning