2009
DOI: 10.1021/es900522v
|View full text |Cite
|
Sign up to set email alerts
|

A Passive Sampler with Improved Performance for Collecting Gaseous and Particulate Phase Polycyclic Aromatic Hydrocarbons in Air

Abstract: A passive sampler which can be used to collect both gaseous and particulate phase polycyclic aromatic hydrocarbons (PAHs) in air was previously developed and calibrated. The sampler was successfully used in a field study in North China Plain. However, the relatively low uptake rate for particulate phase PAHs prevented it from being applied in nonseverely contaminated environment. The sampler was redesigned to increase the uptake rate for particulate phase PAHs and calibrated in the field for individual PAH com… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
18
1
2

Year Published

2011
2011
2018
2018

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 47 publications
(22 citation statements)
references
References 17 publications
1
18
1
2
Order By: Relevance
“…The sampler has been tested in field conditions at different meteorological conditions with satisfaction and detailed calibration and uptake rates of this sampler were described previously (Tao et al, 2009). It is important to note that this passive air sampler samples the particle-bound PAHs less efficiently than gas-phase PAHs.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The sampler has been tested in field conditions at different meteorological conditions with satisfaction and detailed calibration and uptake rates of this sampler were described previously (Tao et al, 2009). It is important to note that this passive air sampler samples the particle-bound PAHs less efficiently than gas-phase PAHs.…”
Section: Methodsmentioning
confidence: 99%
“…PUF disks and GFFs were Soxhlet extracted with 100 mL dichloromethane for 12 h (Liu et al, 2007; Tao et al, 2009), and the extracts were concentrated by rotary evaporation to about 1.0 mL, solvent exchanged to n -hexane, and purified on an alumina silica packed column (10 cm, 3% deactivated silica gel, 6 cm, 3% deactivated alumina, and 1 cm anhydrous sodium sulfate). The silica gel, alumina and anhydrous sodium sulfate were baked at 450 °C for 4 h prior to use.…”
Section: Methodsmentioning
confidence: 99%
“…The passive sampler designed by our laboratory [14] was used to collect gaseous and particulate PAHs samples from two sites located at the lakeside near the village and above the lake (Figure 1). A polyurethane foam (PUF) disk (110 mm diameter × 15 mm thick, density 0.024 g · cm −3 ) and a glass fiber filter (GFF, 110 mm diameter) were used as sampling media for gaseous and particulate phase PAHs, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…et al, 2007). 이미 중국에서는 입자상 시료도 채취할 수 있는 PAS가 개발되었다 (Tao et al, 2009;Tao et al, 2007 시료를 채취하는 PAS가 일부 개발되었으나 (Tao et al, 2009;Tao et al, 2007), 기존에 제작된 침적장치 들을 이용하거나 PAS 내부에 침적판을 설치하는 수 준이다. 지금까지 널리 사용되고 있는 PUF-PAS, Harner et al, 2004;Pozo et al, 2004).…”
Section: 전 세계적으로는 2000년대 초반부터 Pops 모니터 링을 위해 Pas를 사용하기 시작했으며 국내에는unclassified