2016
DOI: 10.1016/j.snb.2015.08.013
|View full text |Cite
|
Sign up to set email alerts
|

A patch type non-enzymatic biosensor based on 3D SUS micro-needle electrode array for minimally invasive continuous glucose monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
64
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 85 publications
(64 citation statements)
references
References 28 publications
0
64
0
Order By: Relevance
“…For this reason, many studies focus on the coating of MNs with conductive materials represented by Au, Pt, and Ag/AgCl as the WEs, counter electrodes (CEs), and reference electrodes (REs), respectively, in order to enable an MN to function as an electrochemical electrode. In this methodology, metal [ 40 46 ], epoxy [ 47 49 ], SU-8 [ 50 53 ], and polymer [ 53 – 59 ] MNs are coated with metal layers using electroplating or vapor deposition. The covering metal layers are connected to the extract electrodes and the measurement system to conduct the input and output signals.…”
Section: Mns As Sensing Probesmentioning
confidence: 99%
“…For this reason, many studies focus on the coating of MNs with conductive materials represented by Au, Pt, and Ag/AgCl as the WEs, counter electrodes (CEs), and reference electrodes (REs), respectively, in order to enable an MN to function as an electrochemical electrode. In this methodology, metal [ 40 46 ], epoxy [ 47 49 ], SU-8 [ 50 53 ], and polymer [ 53 – 59 ] MNs are coated with metal layers using electroplating or vapor deposition. The covering metal layers are connected to the extract electrodes and the measurement system to conduct the input and output signals.…”
Section: Mns As Sensing Probesmentioning
confidence: 99%
“…Enzymatic catalysts usually possess high selectivity and catalytic effectivity, and are suitable for most biomedical applications. Representatives of non-enzymatic catalysts are nanomaterials including nanoporous Pt [113], Pt black [114], Pd nanoclusters [115], and so on. Compared with the enzymatic catalyst, the non-enzymatic catalyst has better stability, less environmental requirements, and is easier to store.…”
Section: Electrochemistrymentioning
confidence: 99%
“…70 The microneedles were patterned from 316-L grade stainless-steel by using jet of ferric chloride wet chemical etchant under the pressure of 2 kg f cm −2 for 60 s. The needles were then punched-out to bend them to 90…”
Section: In-vivo Non-enzymatic Microneedle Glucose Sensorsmentioning
confidence: 99%