2011
DOI: 10.1016/j.talanta.2011.03.039
|View full text |Cite
|
Sign up to set email alerts
|

A polar-copolymerized method to prepare silica-based anion exchanger for ion chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 17 publications
1
8
0
Order By: Relevance
“…The slopes of the hyoscyamine, propranolol, scopolamine and amitriptyline plots are −0.9198, −0.8843, −0.9148 and −0.8573, respectively. These slopes are close in value to the theoretical slope of −1.0 for the cationexchange elution of a singly charged cation [30].…”
Section: Separation Mechanismsupporting
confidence: 80%
“…The slopes of the hyoscyamine, propranolol, scopolamine and amitriptyline plots are −0.9198, −0.8843, −0.9148 and −0.8573, respectively. These slopes are close in value to the theoretical slope of −1.0 for the cationexchange elution of a singly charged cation [30].…”
Section: Separation Mechanismsupporting
confidence: 80%
“…The enhanced attention was paid on the preparation of RPLC/HILIC MMC packing to expand the applications of this kind of stationary phase, e.g. "click β-cyclodextrin" stationary phase [15], imidazoline polymerized silica (SiO 2 ) [6], polymethacrylate with sulfobetaine groups immobilized capillary column [16], humic acid bonded aminopropyl SiO 2 [17], poly(acrylic acid-co-butyl acrylate) grafted SiO 2 [18], M A N U S C R I P T A C C E P T E D ACCEPTED MANUSCRIPT 4 poly-L-Lysine modified SiO 2 [8], peptide Boc-Phe-Aib-Phe-OH immobilized SiO 2 [9], etc.. Liang's group developed the "polar-copolymerized" approach for preparation of polar-modified RPLC stationary phases with various embedded polar or ion groups [19][20][21][22]. Moreover, a commercialized RPLC/HILIC MMC stationary phase was available as Acclaim Mixed-Mode HILIC-1 LC column [10].…”
Section: A N U S C R I P Tmentioning
confidence: 99%
“…The final activity (A f ) of the solution was also measured after 3h wh ich was sufficient time to attain the equilibriu m [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26]. The activ ity measured at various time intervals was corrected for background counts.…”
Section: Study On Kinetics Of Iodi De Ion-isotopic Exchange Reactionmentioning
confidence: 99%
“…Preliminary studies show that the above exchange reactions are of first order [27,28]. Therefore logarith m of activity when plotted against time gives a co mposite curve in which the activity initially decreases sharply and thereafter very slowly giving nearly straight line (Figure 1), evidently rapid and slow ion-isotopic exchange reactions were occurring simu ltaneously [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26]. Now the straight line was extrapolated back to zero time.…”
Section: Comparati Ve Study Of Ion-isotopic Exchange Reactionsmentioning
confidence: 99%