2021
DOI: 10.1016/j.jacep.2020.09.010
|View full text |Cite
|
Sign up to set email alerts
|

A Predictive Model for the Long-Term Electrical Performance of a Leadless Transcatheter Pacemaker

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(15 citation statements)
references
References 12 publications
0
15
0
Order By: Relevance
“…Our study also confirms the excellent long-term electrical performance of LL devices. This information, together with recent work putting forward a number of predictors of poor LL electrical performance, suggest that LL long-term performance is not only highly efficient but has also a significant degree of predictability [ 20 ]. Lastly, our multivariate analysis on survival did not identify any significant factor associated with all-cause mortality at follow-up, with the exception of age, whose associated comorbidities pose a heavy burden of non-cardiovascular mortality ( Table 3 , Figure 2 and Figure 3 ).…”
Section: Discussionmentioning
confidence: 99%
“…Our study also confirms the excellent long-term electrical performance of LL devices. This information, together with recent work putting forward a number of predictors of poor LL electrical performance, suggest that LL long-term performance is not only highly efficient but has also a significant degree of predictability [ 20 ]. Lastly, our multivariate analysis on survival did not identify any significant factor associated with all-cause mortality at follow-up, with the exception of age, whose associated comorbidities pose a heavy burden of non-cardiovascular mortality ( Table 3 , Figure 2 and Figure 3 ).…”
Section: Discussionmentioning
confidence: 99%
“…Recently, Micra was developed to avoid complications of traditional transvenous pacing systems. 1 , 2 Micra is a single-chamber pacemaker, and there is limited clinical research data about the feasibility and safety of the long-term implantation of Micra 6 ; therefore, older patients with symptomatic bradycardiac atrial fibrillation are good candidates for Micra implantation. Older patients are likely to have many comorbidities, such as atrial fibrillation and dementia.…”
Section: Discussionmentioning
confidence: 99%
“…The pacing impedance after fixation has been reported to be associated with the capture threshold during the follow‐up period 10–12 . Kiani et al 10 showed that a pacing impedance of <800 Ω at implantation was related to an elevated capture threshold at 12 months.…”
Section: Discussionmentioning
confidence: 99%
“…The pacing impedance after fixation has been reported to be associated with the capture threshold during the follow‐up period 10–12 . Kiani et al 10 showed that a pacing impedance of <800 Ω at implantation was related to an elevated capture threshold at 12 months. Other reports have identified a pacing impedance at implantation of >600 Ω or 660 Ω as a predictor of an acceptable threshold 11,12 .…”
Section: Discussionmentioning
confidence: 99%