2005
DOI: 10.1109/tpwrs.2004.831696
|View full text |Cite
|
Sign up to set email alerts
|

A Predictor/Corrector Scheme for Obtaining Q-Limit Points for Power Flow Studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
56
1

Year Published

2008
2008
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 60 publications
(59 citation statements)
references
References 20 publications
2
56
1
Order By: Relevance
“…Illconditioned case occurs when a system with high ratios of lines R/X , weak interconnection system [2] or heavy loading at some buses [12,36]. All of these factors affected the stability of both methods.…”
Section: Conventional Load Flow Methodsmentioning
confidence: 99%
“…Illconditioned case occurs when a system with high ratios of lines R/X , weak interconnection system [2] or heavy loading at some buses [12,36]. All of these factors affected the stability of both methods.…”
Section: Conventional Load Flow Methodsmentioning
confidence: 99%
“…CPF is widely used as a powerful tool for tracing power-voltage (P-V) curves and thereby obtaining λmax [1][2][3][4][5][6].…”
Section: Continuation Power Flow Techniquementioning
confidence: 99%
“…Various approaches have been proposed for identifying this margin. One of the main approaches, the continuation power flow (CPF) [1][2][3] has a wide range of applications [4][5][6]. The collapse point method [7], sequential quadratic programming (SQP) algorithm, interior point (IP) optimization method [8].…”
Section: Introductionmentioning
confidence: 99%
“…Since the PoC method is unable to cope with LIB [6], the CPF [1,2] is employed to handle the constraint, i.e., Equation (5) for the purpose of obtaining feasible position of particles that locates on S. The CPF could compute the critical point exactly and is robust and flexible to take into account nonlinear control and inequality constraints. In order to reduce computation time, the best overall approach is to use the conventional power flow method and the CPF analysis in a complementary manner.…”
Section: Application Of Mgcpso To Determine the Shortest Distance To mentioning
confidence: 99%
“…Various methodologies have been proposed for identifying this margin. The continuation power flow (CPF) solved the divergence problem of power flow equation [1,2] and has a wide range of applications such as evaluation of the power system static behavior due to load and/or generation variation with or without control devices [3][4][5]. According to the characteristic of the load flow Jacobian being singular at the point of voltage stability, the point of collapse (PoC) method [6] determines the accurate Saddle Node Bifurcation (SNB) in power systems effectively.…”
Section: Introductionmentioning
confidence: 99%