2013
DOI: 10.1088/1674-1137/37/10/108002
|View full text |Cite
|
Sign up to set email alerts
|

A program for SAXS data processing and analysis

Abstract: A computer program for small angle X-ray scattering (SAXS) data processing and analysis named S.exe written in Intel Visual Fortran has been developed. This paper briefly introduces its main theory and function.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
89
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 136 publications
(91 citation statements)
references
References 24 publications
2
89
0
Order By: Relevance
“…The specific surface area (S SAXS ) from SAXS data can be obtained by the Porod’s law and the invariant (Fig. S4)32. The results show that the S SAXS of FPC and VFPC are 2870 and 3125 m 2  g −1 , respectively.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The specific surface area (S SAXS ) from SAXS data can be obtained by the Porod’s law and the invariant (Fig. S4)32. The results show that the S SAXS of FPC and VFPC are 2870 and 3125 m 2  g −1 , respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Irregular geometric structures are also characteristics of the samples, which can be quantified by the fractal analysis with SAXS method32. The SAXS intensity from fractal samples obeys a power-law form, I = I 0 q −α , where α can be used to determine the fractal type and dimensions (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…2.1 Requirement of calibration precision LHAASO-WCDA requires that the radiation direction reconstruction error is better than 0.1 • [6]. Assuming that 1) in 36 (6×6) detector cells (called a cluster), 20 detector units are triggered by a low energy shower; 2) the time offsets between the average value of the calibration unit error is dT; 3) the distance between the detector and shower axis is L = 7.5 m for geometric assumptions, then dT must satisfy:…”
Section: Time Calibration Systemmentioning
confidence: 99%
“…It can be seen that there is a positive deviation from Porod's law. According to Li et al [16] and Li [25], this positive deviation means that the electron density changes abruptly in the Al-matrix melt and there is a sharp boundary rather than a diffuse interface layer between Bi-rich droplets and Al-matrix melt. So we think that the LPSP occurs as the nucleation of Bi-rich droplets directly from the supersaturated Al-matrix melt rather than a homogeneous spinodal reaction.…”
Section: Occurrence Mechanism Of the Liquid Phase Separationmentioning
confidence: 99%