1999
DOI: 10.1007/s100169900241
|View full text |Cite
|
Sign up to set email alerts
|

A Prospective Evaluation of PTFE Graft Patency and Surveillance Techniques in Hemodialysis Access

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
37
4
2

Year Published

2003
2003
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 79 publications
(45 citation statements)
references
References 19 publications
2
37
4
2
Order By: Relevance
“…Indeed, the overall primary and secondary AVG patency (80 and 83% in 12 months, respectively) were comparable with data on AVF constructed with native vessels. In addition, our data are better than what other studies report on primary and secondary patency of prostheses made of PTFE or PUU [2, 3]. …”
Section: Discussioncontrasting
confidence: 70%
See 1 more Smart Citation
“…Indeed, the overall primary and secondary AVG patency (80 and 83% in 12 months, respectively) were comparable with data on AVF constructed with native vessels. In addition, our data are better than what other studies report on primary and secondary patency of prostheses made of PTFE or PUU [2, 3]. …”
Section: Discussioncontrasting
confidence: 70%
“…Moreover, in these patients, the positioning of a ‘long-term’ central venous catheter has a limited duration because of the high rate of thrombotic and infective complications, for which a secondary alternative is to place a biological or a synthetic prosthetic arteriovenous graft (AVG). In this regard, the most used vascular prostheses are those made of polytetrafluoroethylene (PTFE) or polyurethane urea (PUU) [2,3,4], which are usually placed in the forearm and use the deep circle of the accompanying veins as a venous downflow. Although the creation of a prosthetic arteriovenous access using expanded PTFE is technically simple and the short-term results are usually good, with a 90% reported primary patency rate at 6 weeks [2], the long-term patency of these devices is unsatisfactory, the 1-year cumulative secondary patency rate being 36% with none of the grafts patent at 3 years in a recently reported experience [2].…”
Section: Introduction and Aims Of The Studymentioning
confidence: 99%
“…5 These rates are comparable to those of ePTFE grafts at 1 year of 77% (primary) and 64% (secondary). 7,8,[13][14][15] The 3-year primary and secondary patency rates in our study of 55% and 72%, respectively, fall within the standards set by the National Kidney Foundation, 16 which recommends that the cumulative patency rates of all dialysis AV grafts should be at least 70% at 1 year, 60% at 2 years, and 50% at 3 years.…”
Section: Discussionmentioning
confidence: 75%
“…However, numerous prospective studies evaluating the standard ePTFE grafts report primary or assisted primary patency rates that range from Ͻ10% to as high as 43%. 18,[23][24][25][26] Two recent prospective studies of cuffed ePTFE grafts also reported widely discrepant results. 18,27 The first study from the Mayo Clinic demonstrated a 1-year primary patency rate for cuffed ePTFE (n ϭ 24) and standard ePTFE (n ϭ 24) grafts of 35% and Ͻ10%, respectively.…”
Section: Discussionmentioning
confidence: 99%