2008
DOI: 10.1530/eje-07-0403
|View full text |Cite
|
Sign up to set email alerts
|

A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17β-estradiol in prepubertal children

Abstract: A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17b-estradiol in prepubertal children Carina Ankarberg-Lindgren and Ensio Norjavaara Department of Paediatrics, Institute of Clinical Sciences, The Sahlgrenska Academy at Göteborg University, S-416 85, Göteborg, Sweden (Correspondence should be addressed to C Ankarberg-Lindgren; Email: carina.ankarberg-lindgren@vgregion.se) AbstractObjective: To test the clinical usefulness of sensit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
47
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 53 publications
(49 citation statements)
references
References 23 publications
(28 reference statements)
2
47
0
Order By: Relevance
“…Serum E 2 concentrations were determined in duplicate by an assay which involves a diethyl ether extraction step prior to radioimmunoassay (Spectria® Estradiol RIA; Orion Diagnostica, Espoo, Finland) [1,6]. The extraction E 2 radioimmunoassay has been validated especially for pediatric use [6] and is accredited by the SWEDAC quality control agency in Sweden, SS-EN ISO 15189 (No.…”
Section: Methodsmentioning
confidence: 99%
“…Serum E 2 concentrations were determined in duplicate by an assay which involves a diethyl ether extraction step prior to radioimmunoassay (Spectria® Estradiol RIA; Orion Diagnostica, Espoo, Finland) [1,6]. The extraction E 2 radioimmunoassay has been validated especially for pediatric use [6] and is accredited by the SWEDAC quality control agency in Sweden, SS-EN ISO 15189 (No.…”
Section: Methodsmentioning
confidence: 99%
“…Serum oestradiol (E 2 ) concentrations were determined using an assay that involves a diethyl ether extraction step prior to quantification by a modified RIA (Spectria Estradiol RIA, Orion Diagnostica; Espoo, Finland) as described previously (21). The lower limit of detection for the extraction RIA was 4 pmol/l.…”
Section: Methodsmentioning
confidence: 99%
“…Sex hormone binding globulin (SHBG) levels were measured using solid-phase, chemiluminescent immunometric assays (Immulite 1000, Diagnostic Products Corporation, Los Angeles, CA, USA). Serum 17β-estradiol (E2) was determined in duplicate by extraction RIA as previously described 17 and testosterone levels as previously described 18 . E2 and testosterone were utilized together with SHBG in calculating the free E2 and free testosterone levels, respectively, according to a previously presented method 19 .…”
Section: Blood Samplingmentioning