2005
DOI: 10.1016/j.aca.2005.04.067
|View full text |Cite
|
Sign up to set email alerts
|

A radiofrequency plasma in a polydimethylsiloxane (PDMS) microchip

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…Rotational temperature of plasmas was estimated using Boltzmann plots and the Q1 branch from Q 1 (2) to Q 1 (14) in the 3075-3115 Å region of the OH radical. Figure 2 shows OH spectrum generated by the He-plasma.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Rotational temperature of plasmas was estimated using Boltzmann plots and the Q1 branch from Q 1 (2) to Q 1 (14) in the 3075-3115 Å region of the OH radical. Figure 2 shows OH spectrum generated by the He-plasma.…”
Section: Resultsmentioning
confidence: 99%
“…Various types of micro plasmas have been recently described, such as, CCP, 7-9 MIP, 4,10,11 ICP, 12,13 and others, which can detect halogens. However, argon plasmas have insufficient energy to excite halogens, 14 and thus, helium has been used instead due to the higher excitation and ionization energy. The thermal properties of plasmas can be estimated using several techniques, such as, mass spectrometry, Langmuir probe, and optical techniques.…”
Section: Introductionmentioning
confidence: 99%
“…Then, the microarray chips were treated with oxygen plasma for 30 s to render the exposed PDMS pillars hydrophilic. 24,25 3-Glycidoxypropyl-trimethoxysilane (GPTMS, 98%, Sigma-Aldrich) was inserted as a linker on the pillars to improve the reactivity and immobilization efficiency of IgG. For this, 500 mL of GPTMS was deposited on each chip by chemical vapor deposition in a vacuum of 70 Torr at 100 C for 2 h. Then, each chip was washed with ethyl alcohol (99.9%, Duksan, Korea) and dried with flowing He gas.…”
Section: Experimental Immobilization Of Immunoglobulin G (Igg) On Mic...mentioning
confidence: 99%
“…RF power of 500 W and 50 kHz (Corona Treatment Generator HK-2000, Hankook High Frequency, Goyang-si, Korea) was used for 30 s at atmospheric pressure for the plasma treatment, optimized in the lab. 23,24 Finally, the PDMS plate with 5 Â 5 and 6 Â 7 arrays of islands, $150 mm in diameter and 100 mm in height, was cut into $4 Â 4 mm chips. Since the hydrophilic surface is unstable due to the diffusion of low molecular weight chains, 25,26 the chip with mask film was re-treated if not used within 30 min.…”
Section: Experimental Manufacturing Microchipmentioning
confidence: 99%