2005
DOI: 10.1093/bja/aei234
|View full text |Cite
|
Sign up to set email alerts
|

A randomized non-crossover study comparing the ProSeal™ and Classic™ laryngeal mask airway in anaesthetized children

Abstract: We conclude that ease of insertion, fibreoptic position, and frequency of mucosal trauma are similar for the PLMA and cLMA in children, but oropharyngeal leak pressure is higher and gastric insufflation less common for the PLMA. Gastric tube insertion has a high success rate, provided the PLMA is correctly positioned.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

19
55
4

Year Published

2006
2006
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 63 publications
(78 citation statements)
references
References 15 publications
19
55
4
Order By: Relevance
“…In these studies, neuromuscular blockade was not used and, although the pressure was not visible to the observer, the observer was not blinded to which airway device was used. Shimbori et al 18 performed a randomized, non-blinded study in 19 showed a difference in leak pressure between groups (PLMA 33 cm H 2 O; CLMA 26 cm H 2 O), as well as a higher incidence of gastric insufflation with the CLMA, with no difference in fibreoptic view. These mean leak pressures far exceed those observed in the studies previously described [15][16][17][18] as well as the current investigation.…”
Section: Discussionmentioning
confidence: 99%
“…In these studies, neuromuscular blockade was not used and, although the pressure was not visible to the observer, the observer was not blinded to which airway device was used. Shimbori et al 18 performed a randomized, non-blinded study in 19 showed a difference in leak pressure between groups (PLMA 33 cm H 2 O; CLMA 26 cm H 2 O), as well as a higher incidence of gastric insufflation with the CLMA, with no difference in fibreoptic view. These mean leak pressures far exceed those observed in the studies previously described [15][16][17][18] as well as the current investigation.…”
Section: Discussionmentioning
confidence: 99%
“…Sufficient ventilation was judged clinically by the presence of symmetric chest movements, stable oxygen saturation, stable square wave capnography trace with no audible oropharyngeal leak, and a tidal volume of at least 6 ml/kg body weight. 17,20 Minor airway interventions were recorded.…”
Section: Measurementsmentioning
confidence: 99%
“…These devices all incorporate a drain tube to separate the respiratory and gastrointestinal tracts and minimise the risk of aspiration. They also create a higher oropharyngeal leak pressure compared with the first generation SADs [4][5][6][7][8] …”
Section: Definitions and Devicesmentioning
confidence: 99%