A rapid and quantitative technique for assessing IgG monomeric purity, calibrated with the NISTmAb reference material

Abstract: The fraction of intact monomer in a sample (moles/moles), the monomeric purity, is measured as a quality control in therapeutic monoclonal antibodies but is often unknown in research samples and remains a major source of variation in quantitative antibody-based techniques such as immunoassay development. Here, we describe a novel multiplex technique for estimating the monomeric purity and antigen affinity of research grade antibody samples. Light scattering was used to simultaneously observe the mass of antibo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 36 publications
1
7
0
Order By: Relevance
“…The hydrodynamic size of the native IgG was found to be ∼5 nm, in agreement with the literature ( Hawe et al, 2011 ). The absorbance of native IgG was 0.172, which corresponded to 0.1 mg/mL of IgG using Beer Lambert's law ( Reader et al, 2019 ). The effects of varying temperature and combined UV and temperature with time were evaluated at the conditions suggested by Design-Expert software ( Table 2 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The hydrodynamic size of the native IgG was found to be ∼5 nm, in agreement with the literature ( Hawe et al, 2011 ). The absorbance of native IgG was 0.172, which corresponded to 0.1 mg/mL of IgG using Beer Lambert's law ( Reader et al, 2019 ). The effects of varying temperature and combined UV and temperature with time were evaluated at the conditions suggested by Design-Expert software ( Table 2 ).…”
Section: Resultsmentioning
confidence: 99%
“…To estimate the final concentration of the stock solution, the absorbance values were measured using a UV spectrophotometer (Thermo Scientific; Evolution 201) at 280 nm. The stock concentration was calculated using Beer Lambert's law with the extinction coefficient value of 210,000 M -1 cm -1 ( Reader et al, 2019 ). A final concentration of 0.1 mg/mL was prepared as a working solution for further usage.…”
Section: Methodsmentioning
confidence: 99%
“…However, the antibody orientation on the sensor surface can be interrogated using an Fc-presenting assay by passing PAG over the surface. The surface density and orientation of antibodies produce a measure of quality control in the manufacture of the assay arrays 19 .…”
Section: Experimental Methods and Materialsmentioning
confidence: 99%
“…The assay platform has been optimised for two assays, C-reactive protein (CRP) and total IgG both have commercial interest. Total IgG provides useful information about antibody integrity 19 and in-line QC of the materials on delivery supporting both the CRP assay and the total IgG assay. CRP is the target clinical assay and is the subject of ~5,000 publications per year (PubMed) as a sensitive but not specific biomarker of systemic inflammation in many conditions such as sepsis 20 .…”
Section: Introductionmentioning
confidence: 99%
“…The tests were performed on the portable bench-top multiplexed array technology that has been described in detail elsewhere. [6][7][8][9][10] It has been shown effective at detecting antibody in response to vaccination 11 and has characterised accuracy and precision for CRP and total IgG assays 6 with typically 10% accuracy and intra-day precision of less than 5%. The technology consists of an array of 170 of gold nanoparticle spots which scatter light into a video camera when illuminated from below ( Fig.…”
Section: Multiplexed Covid-19 Antigen Array and Liscar Readermentioning
confidence: 99%