2007
DOI: 10.2116/analsci.23.1443
|View full text |Cite
|
Sign up to set email alerts
|

A Rapid Sample Pretreatment Protocol: Improved Sensitivity in the Detection of a Low-abundant Serum Biomarker for Prostate Cancer

Abstract: The detection of small and low abundant biomarkers in clinical samples remains a challenge, mainly due to the presence of high-abundant proteins, such as albumin (HSA) and immunoglobulin G (IgG), accounting for at least 65% of plasma proteins. 1 The depletion of these proteins could facilitate biomarker discovery and detection. Depletion should aim to provide the selective removal of high-abundant proteins, and concentrate components of low abundance. Commercially available methods for IgG and HSA depletion ha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2007
2007
2013
2013

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 19 publications
0
10
0
Order By: Relevance
“…It is also important to consider other factors that may affect serum protein levels including psychological stress, time of blood sample collection, time since last meal, or uncontrolled differences in specimen handling [213,214]. Many of these limitations are beginning to be addressed [215,216] increasing the feasibility of comprehensive diagnostic testing in plasma. To this end, preliminary studies examining patterns of biomolecules, including proteins and autoantibodies, have been undertaken with some success for diseases such as graft versus host disease [217], chronic pancreatitis [198], brain cancer [218], lung cancer [219,220] and idiopathic pulmonary fibrosis (IPF) [221].…”
Section: Clinical Sample Typementioning
confidence: 99%
“…It is also important to consider other factors that may affect serum protein levels including psychological stress, time of blood sample collection, time since last meal, or uncontrolled differences in specimen handling [213,214]. Many of these limitations are beginning to be addressed [215,216] increasing the feasibility of comprehensive diagnostic testing in plasma. To this end, preliminary studies examining patterns of biomolecules, including proteins and autoantibodies, have been undertaken with some success for diseases such as graft versus host disease [217], chronic pancreatitis [198], brain cancer [218], lung cancer [219,220] and idiopathic pulmonary fibrosis (IPF) [221].…”
Section: Clinical Sample Typementioning
confidence: 99%
“…In their own turn, most immunostrips have nanomolar level sensitivity, whereas CNT‐based biosensors go down to picomolar concentrations 54–56. NP‐enhanced immunostrips also increase essentially the sensitivity of biosensors for clinical samples 57, 58. Future developments of nanobiochips for POCD enable the clinician to make the diagnosis directly at the bedside.…”
Section: Towards Medicinal Nanobiochipsmentioning
confidence: 99%
“…Because of the specific binding of protein G to the F c region of IgG, it has been extensively used to deplete serum IgG 8–10, 30, 38. Protein G was also used in a preconcentrator‐capillary zone electrophoresis system for the extraction of IgG from human serum 39.…”
Section: Depletion Methodsmentioning
confidence: 99%