2010
DOI: 10.1016/j.diagmicrobio.2009.09.004
|View full text |Cite
|
Sign up to set email alerts
|

A rapid, simple, and sensitive loop-mediated isothermal amplification method to detect toxigenic Vibrio cholerae in rectal swab samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
40
0
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 51 publications
(43 citation statements)
references
References 14 publications
2
40
0
1
Order By: Relevance
“…In general, molecular level-based detection methods such as PCR and LAMP are subjected to a variety of inhibitors present in clinical samples. Some researchers have reported that the Bst polymerase in LAMP is less sensitive to the presence of inhibitors than the Taq polymerase used in classic PCR [25], [26]. Our results showed that the LAMP assay is more accurate and sensitive than qPCR methods using simulated human stool samples, and proved markedly faster than qPCR by at least 20 min, thereby significantly shortening the total assay time.…”
Section: Discussionmentioning
confidence: 58%
“…In general, molecular level-based detection methods such as PCR and LAMP are subjected to a variety of inhibitors present in clinical samples. Some researchers have reported that the Bst polymerase in LAMP is less sensitive to the presence of inhibitors than the Taq polymerase used in classic PCR [25], [26]. Our results showed that the LAMP assay is more accurate and sensitive than qPCR methods using simulated human stool samples, and proved markedly faster than qPCR by at least 20 min, thereby significantly shortening the total assay time.…”
Section: Discussionmentioning
confidence: 58%
“…Of the 42 samples, 26 tested positive by LAMP assay, while only 1 and 3 samples tested positive by nested PCR and real-time PCR, respectively. Some researchers have reported that the Bst polymerase in LAMP is less sensitive to the presence of inhibitors than is the Taq polymerase used in PCR (8,16,13). Thus, although nested PCR (1, 9) and real-time PCR (5,18) have been reported to be more sensitive than the LAMP assay for the detection of A. phagocytophilum, in this study, the LAMP assay was shown to be more accurate and more sensitive than PCR methods on clinical samples.…”
Section: Discussionmentioning
confidence: 69%
“…Thus, we suggest that A. phagocytophilum infection When evaluating the specificity of the msp2 LAMP assay, we tested 27 members of the order Rickettsiales and other pathogenic bacteria, and the results of this study showed that the specificity of the LAMP assay is 100%. The high specificity of LAMP methods has also been reported for other pathogens (4,11,13,14,16). Compared to conventional PCR techniques, 6 LAMP primers were designed to target 8 regions, while PCR methods used primers targeting 2 to 4 regions.…”
Section: Discussionmentioning
confidence: 99%
“…Individual colonies were selected and cultured for 18 h at 37°C on Tryptic Soy Broth (TSB) (Difco, Detroit, MI). In addition, Loop-mediated isothermal amplification (LAMP) [25] was performed to screen for toxigenic V. cholerae among approximately 2,000 samples. Biotyping of the isolates was carried out using the Voges-Proskauer (VP) reaction and polymyxin B (50 units) [26].…”
Section: Methodsmentioning
confidence: 99%