2005 International Conference on Electrical Machines and Systems 2005
DOI: 10.1109/icems.2005.202865
|View full text |Cite
|
Sign up to set email alerts
|

A ratio variation of equivalent instantaneous inductance based method to identify magnetizing inrush in transformers

Abstract: In terms of the characteristic of instantaneous magnetizing inductance reflecting the saturation stage in transformer, an improved method is proposed to distinguish between the magnetizing inrush current and short-circuit fault based on the ratio of average equivalent instantaneous inductances between the non-saturation and the saturation zone, which are divided according to a threshold of differential current. During the inrush, the value of equivalent instantaneous inductance varies severely from small to la… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…To distinguish between inrush currents and internal faults in , the information of iron losses and the B–H curve are not required. In , equivalent instantaneous inductance is used to identify the inrush current. But none of these studies have modeled the ultra‐saturation phenomenon.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…To distinguish between inrush currents and internal faults in , the information of iron losses and the B–H curve are not required. In , equivalent instantaneous inductance is used to identify the inrush current. But none of these studies have modeled the ultra‐saturation phenomenon.…”
Section: Introductionmentioning
confidence: 99%
“…To distinguish between inrush currents and internal faults in [31], the information of iron losses and the B-H curve are not required. In [32,33], equivalent instantaneous inductance is used to identify the inrush current. But none of these studies have modeled the ultra-saturation phenomenon.In [3][4][5], the mal-operation of the differential protection during the energization of a loaded power transformer, whose extraction is known as an ultra-saturation phenomenon, was reported.…”
mentioning
confidence: 99%
“…To distinguish between the inrush current and the internal faults in [31], the information of iron losses and B-H curve are not required. In [32,33], Equivalent instantaneous inductance was used to identify the inrush current. In [34][35][36][37][38][39][40], the wavelet transform technique and fuzzy approach were used distinguish between the internal faults and the inrush current.…”
mentioning
confidence: 99%