2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia) 2017
DOI: 10.1109/ifeec.2017.7992134
|View full text |Cite
|
Sign up to set email alerts
|

A reactive power control strategy of the grid-connected inverter for microgrid application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(10 citation statements)
references
References 10 publications
0
10
0
Order By: Relevance
“…Conventional methods OLTC transformers [51, 63, 91, 96, 97] DFIG [57, 62, 8790, 95] SCIM [1] Capacitor banks [14, 16, 30, 32, 50, 105] Static VAR system [29, 31, 49, 60, 70, 92, 107] …”
Section: Analysis Of the Type Of Control Grid Code And Type Of Regsmentioning
confidence: 99%
See 2 more Smart Citations
“…Conventional methods OLTC transformers [51, 63, 91, 96, 97] DFIG [57, 62, 8790, 95] SCIM [1] Capacitor banks [14, 16, 30, 32, 50, 105] Static VAR system [29, 31, 49, 60, 70, 92, 107] …”
Section: Analysis Of the Type Of Control Grid Code And Type Of Regsmentioning
confidence: 99%
“…Most of the collected research papers (refer to Table 2) have been implemented in MATLAB/Simulink software (49 literature works). The microprocessor has been used as an implementation tool in [3] and [14]. In addition, PSCAD/EMTDC software in [32], DIgSILENT/PowerFactory in [34], dSPACE ds1104 based system in [42], DigSILENT software in [46] and OPAL‐RT's eMEGASIM and ePHASORSIM [86], PSIM software [59, 63, 64, 67, 70], MATLAB and PSIM co‐simulation platform [71], ARM CORTEX processor [75], DlgSI LENT/PowerFactory [60]: FORTRAN programming language [92], MATLAB/Simulation [1, 2, 4, 31, 39, 45, 48, 4958, 62, 65, 66, 68, 69, 72, 7374, 7785, 88, 91, 9394, 96, 97, 99, 100103, 107, 105, 106], software PSIM [89], DIgSILENT/PowerFactory [90], ETAP simulation platforms [29], DIgSILENT/PowerFactory [34], HiL tests in the PLECS settings [104], OPAL‐RT's eMEGASIM and ePHASORSIM [86], PSCAD/EMTDC [87] have been used as implementation tools.…”
Section: Analysis Of the Type Of Control Grid Code And Type Of Regsmentioning
confidence: 99%
See 1 more Smart Citation
“…In [9] and [10], the active and reactive power control of the inverter was realized. In [11], to prevent the voltage rise at the grid connection point of the PV systems, the reactive power adjusted through the inverter's reactive current control. In article [12], the reactive power of the inverter was controlled by the Quasi Sinusoidal Waveform method.…”
Section: Introductionmentioning
confidence: 99%
“…The active-reactive power production balance of the inverter output was controlled in [16][17][18]. The reactive power control of the inverter was made by reactive current control in [19]. In [20], the response of the inverter to the unexpected conditions in the grid was analyzed.…”
Section: Introductionmentioning
confidence: 99%