1992
DOI: 10.1109/59.207326
|View full text |Cite
|
Sign up to set email alerts
|

A real and reactive power control approach for battery energy storage system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

1995
1995
2019
2019

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…The constraint on the storage commitment is represented by (10) and charge/discharge capacity limits are shown in (11), (12). The reactive power supplied by power electronic interface of the storage unit is shown in (13) [20]. The available energy at hour is shown in (14) which is dependent on the available energy at hour and the charged/discharged energy at hour .…”
Section: Optimal Operation Of Microgridsmentioning
confidence: 99%
See 1 more Smart Citation
“…The constraint on the storage commitment is represented by (10) and charge/discharge capacity limits are shown in (11), (12). The reactive power supplied by power electronic interface of the storage unit is shown in (13) [20]. The available energy at hour is shown in (14) which is dependent on the available energy at hour and the charged/discharged energy at hour .…”
Section: Optimal Operation Of Microgridsmentioning
confidence: 99%
“…Equation (19) shows the admittance of distribution lines. The linearized formulation of real/reactive power injections are given in (20), (21). Equations (22) and (23) show the linearized formulation of real and reactive line flow and (24) represents the apparent power flow through the distribution line.…”
Section: Optimal Operation Of Microgridsmentioning
confidence: 99%
“…equivalent inductive electromotor) should be guaranteed, so the ΔP d should be selected into the output function. Lastly, to guarantee the controlling precision, ΔI BEd should also be selected [13]- [15].…”
Section: Integrated Mathematical Load Model With Connected Bessmentioning
confidence: 99%
“…Severe situation now gives rise to the LVRT (Low Voltage Ride Through) technology. LVRT of wind power means that wind generator can be connected to grid like thermal power generators when voltage sags in the grid with high proportion of wind power [2,3]. Meanwhile, there should be some reactive power offered to power grid to help to rebuilt grid voltage.…”
Section: Introductionmentioning
confidence: 99%