2021
DOI: 10.1111/dom.14439
|View full text |Cite
|
Sign up to set email alerts
|

A real‐world study of user characteristics, safety and efficacy of open‐source closed‐loop systems and Medtronic 670G

Abstract: We report a real-world evaluation of the first commercially approved automated insulin delivery (AID) system, MiniMed 670G (670G), and open source-automated insulin delivery (OS-AID) systems. This was undertaken as a retrospective observational study in adults with type 1 diabetes using AID systems for 6 months or longer in a publicly funded health service using clinically validated data. Sixty-eight adults (38 670G, 30 OS-AID systems) were included. OS-AID system users were younger, had a shorter diabetes dur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
37
0
2

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 30 publications
(40 citation statements)
references
References 12 publications
1
37
0
2
Order By: Relevance
“…Recent reviews of the evidence highlight high levels of user satisfaction and quality of life outcome measures are positive, with excellent self-reported outcomes [8,9]. Validated safety and efficacy outcomes have also been reported with encouraging results from a study of Loop in the USA and a recent real-world comparison between Med-Tronic MiniMed 670G and OS-AID systems in UK [7,8,10,11]. Despite many of the individual component parts being approved, tested and available on the NHS, given the strict requirements for MHRA licensing and CE marking these systems, OS-AID systems remain unapproved at present.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recent reviews of the evidence highlight high levels of user satisfaction and quality of life outcome measures are positive, with excellent self-reported outcomes [8,9]. Validated safety and efficacy outcomes have also been reported with encouraging results from a study of Loop in the USA and a recent real-world comparison between Med-Tronic MiniMed 670G and OS-AID systems in UK [7,8,10,11]. Despite many of the individual component parts being approved, tested and available on the NHS, given the strict requirements for MHRA licensing and CE marking these systems, OS-AID systems remain unapproved at present.…”
Section: Introductionmentioning
confidence: 99%
“…At the time of this survey the closest commercially available alternative was the Medtronic MiniMed 670G with hybrid closed-loop technology, which has less functionality than OS-AID [ 10 ]. Additionally, professional guidance was not available for use of open-source AID systems and it was unclear where doctors stood ethically in openly supporting these systems.…”
Section: Introductionmentioning
confidence: 99%
“…Three studies investigated multiple AID systems simultaneously, of which two included various types of open‐source AID 9,11 and one study compared the Medtronic 670G with open‐source AID 29 …”
Section: Resultsmentioning
confidence: 99%
“…Furthermore, the impact of socio‐economic status, ethnicity as well as on individuals with further physical and mental health implications should be considered. A recent report highlights the importance of such studies 29 . It further contrasts the outcomes and participant characteristics, which has important implications for the application of technologies in T1D.…”
Section: Discussionmentioning
confidence: 99%
“…To date, there are no reported issues of this occurring within research leveraging Open Humans. In general, it has been shown elsewhere [ 33 - 35 ] that real-world data are an important and robust source of information in addition to those from clinical trials. Furthermore, we screened both survey and device data for false entries and removed obvious outliers and erroneous entries where necessary.…”
Section: Discussionmentioning
confidence: 99%