1993
DOI: 10.1107/s0108270192009661
|View full text |Cite
|
Sign up to set email alerts
|

A redetermination of monclinic γ-sulfur

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
29
0

Year Published

2004
2004
2016
2016

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(34 citation statements)
references
References 2 publications
5
29
0
Order By: Relevance
“…2 show the corresponding optimized precursors. "Bonds" are indicated at the figures only for those inter-atomic distances that do not differ more than 15% from an average experimentally known distance found in sulfur-organic compounds (namely, for C-S bonds this average experimental value is 1.78 Å, for C-C bonds -1.37 Å, and for S-S bonds 1.98 Å) [19][20][21][22][23].…”
Section: Precursorsmentioning
confidence: 99%
See 1 more Smart Citation
“…2 show the corresponding optimized precursors. "Bonds" are indicated at the figures only for those inter-atomic distances that do not differ more than 15% from an average experimentally known distance found in sulfur-organic compounds (namely, for C-S bonds this average experimental value is 1.78 Å, for C-C bonds -1.37 Å, and for S-S bonds 1.98 Å) [19][20][21][22][23].…”
Section: Precursorsmentioning
confidence: 99%
“…4c), the calculated C-S bond length values vary considerably between 1.75 Å and 2.01 Å [20]. These should be compared to 1.77 Å and 2.04 Å for the CP x analogue of this model system representing the tetragon defect [2].…”
Section: Defects In the Cs X Networkmentioning
confidence: 99%
“…Due to the isotopically enriched and elemental nature of this sample, as well as the very high magnetic field strength used, we suggest that this represents a practical upper limit for 33 S C Q values measurable using currently available solid-state NMR techniques. Precluding any similar study of a pure, enriched sulfur sample of a different phase (e.g., c-sulfur, which is unstable [24]) or allotrope (e.g.,S 6 [25]), the 33 S content of any other sample will be significantly diluted even if isotopically enriched. In addition, any sample with an increased T 2 , which would allow the use of QCPMG enhancement, would be likely to also feature a much longer T 1 , necessitating the use of a longer recycle delay.…”
mentioning
confidence: 99%
“…1) were recorded to investigate the state of the synthesized porous carbon and the sulfur in the C/S materials. Firstly, pure sulfur displays sharp diffraction peaks that agree well with the characteristic pattern of S 8 and conform to F ddd orthorhombic structure [26,27], while both the two carbon materials only show a broad diffraction peak at about 24°, indicating amorphous characteristics. One more observation is that the XRD patterns of carbon synthesized with and without Cu(Ac) 2 involvement are virtually identical, suggesting that the addition of metal salt had little effect on the graphitization degree of carbon.…”
Section: Resultsmentioning
confidence: 59%