2012
DOI: 10.1109/tie.2011.2157288
|View full text |Cite
|
Sign up to set email alerts
|

A Research on Space Vector Modulation Strategy for Matrix Converter Under Abnormal Input-Voltage Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
58
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 84 publications
(58 citation statements)
references
References 24 publications
0
58
0
Order By: Relevance
“…In other words, all the eigenvalues of A-GC should have negative real parts. The characteristic equation of the system is ( ) (27) The gain matrix can be determined by applying the pole placement method. Suppose the observer has a pair of conjugate complex poles a ± jb, then the desired characteristic equation can be expressed as …”
Section: Ac Input Voltage Estimationmentioning
confidence: 99%
See 1 more Smart Citation
“…In other words, all the eigenvalues of A-GC should have negative real parts. The characteristic equation of the system is ( ) (27) The gain matrix can be determined by applying the pole placement method. Suppose the observer has a pair of conjugate complex poles a ± jb, then the desired characteristic equation can be expressed as …”
Section: Ac Input Voltage Estimationmentioning
confidence: 99%
“…(27) and (28) should be identical, and the elements of G can be obtained by matching the coefficients of each power of s as follows:…”
Section: Ac Input Voltage Estimationmentioning
confidence: 99%
“…Compared with "AV method", SVPWM not only increases the maximum voltage transmission ratio from 0.5 to 0.866, but also achieves digitization easily. As a result, SVPWM is currently widely applied [15][16][17]. Therefore, for USMC, the harmonic analysis of output voltage under SVPWM is of important significance.…”
Section: Introductionmentioning
confidence: 99%
“…They are scalar techniques, pulse width modulation (PWM), predictive control, and direct torque control (DTC) [3].The Venturini method [4] is the first scalar technique, which obtains the duty ratio of each switch directly by calculating the function of the instantaneous value of the input voltage and the reference value of the output voltage. The Space vector modulation [5] (SVM) is based on the instantaneous space vector representation of input and output voltages and currents and it exploits the pulse width modulation, which was developed and improved in the 1990s. The modern technique, predictive control [6], [7] evaluates the effect 52 of each possible switching state by a cost function.…”
Section: Introductionmentioning