2021
DOI: 10.4274/tjo.galenos.2020.47629
|View full text |Cite
|
Sign up to set email alerts
|

A Retrospective Analysis of Safety and Efficacy of XEN 45 Microstent Combined Cataract Surgery in Open-Angle Glaucoma over 24 Months

Abstract: Objectives: To evaluate the effect on intraocular pressure (IOP) reduction and safety of ab interno gelatin microstent (XEN 45 Gel Stent; Aquesys, Inc, Aliso Viejo, CA, USA) microincisional glaucoma/cataract surgery in open-angle glaucoma (OAG). Materials and Methods: In this retrospective study, 30 eyes of 25 patients with OAG which underwent XEN 45 implantation combined with simultaneous phacoemulsification were clinically evaluated. Clinical outcomes analyzed include… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
11
1
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 29 publications
2
11
1
2
Order By: Relevance
“…When comparing the results of the current study to those of the XEN45 device, it can be observed that the IOP lowering achieved with XEN63 was consistently greater (see Table 5). Moreover, except for the Hengerer et al study [19], the preoperative IOP of our study was higher than that reported by the other studies [12,[20][21][22][23][24][25][26][27][28][29][30].…”
Section: Discussioncontrasting
confidence: 78%
“…When comparing the results of the current study to those of the XEN45 device, it can be observed that the IOP lowering achieved with XEN63 was consistently greater (see Table 5). Moreover, except for the Hengerer et al study [19], the preoperative IOP of our study was higher than that reported by the other studies [12,[20][21][22][23][24][25][26][27][28][29][30].…”
Section: Discussioncontrasting
confidence: 78%
“…In most studies, the proportion of IOP decreases was >30%. Only 6 studies reported that IOP decreased by <20% (24,30,31,35,49,66). A common feature was found among these studies, which was that the baseline IOP was at a relatively low level of <22 mmHg.…”
Section: Decreasing Iop and Reducing Antiglaucoma Medicationsmentioning
confidence: 99%
“…Dentre as complicações, podemos citar sangramento na câmera anterior 19,34 , hipotonia transitória 19,20 , endoftalmite 17 , descolamento de retina 18,20 , bolhas subconjuntivais 18,24 ou diplopia 31 , que podem estar ligadas as técnicas que os profissionais utilizam, posicionamento incorreto do stent 31 ou em decorrência das drogas que precisam ser utilizadas pós procedimento cirúrgico, como colírios a base de corticoides 27,32,36 e antibióticos 32,37,40 .…”
Section: Discussionunclassified