2022
DOI: 10.3390/life12030342
|View full text |Cite
|
Sign up to set email alerts
|

A Review of Biosensors for Detecting Tumor Markers in Breast Cancer

Abstract: Breast cancer has the highest cancer incidence rate in women. Early screening of breast cancer can effectively improve the treatment effect of patients. However, the main diagnostic techniques available for the detection of breast cancer require the corresponding equipment, professional practitioners, and expert analysis, and the detection cost is high. Tumor markers are a kind of active substance that can indicate the existence and growth of the tumor. The detection of tumor markers can effectively assist the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
22
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 43 publications
(23 citation statements)
references
References 121 publications
(172 reference statements)
1
22
0
Order By: Relevance
“…The diffraction peaks at 2θ = 7.59 and 8.72° reflect the (110) and (002) planes of UiO-66, where 2θ = 12.26, 14.97, 17.28, 22.42, 25.94, and 30.93° represent UiO- 66 (022), (113), (004), (115), (224), and (046) planes. This is consistent with the typical XRD pattern of UiO-66. , Compared to the XRD spectrum of UiO-66, the XRD spectra of Co-UiO-66 are not significantly different, suggesting that the coverage of the Co layer has little effect on the crystal structure of UiO-66.…”
Section: Resultssupporting
confidence: 84%
See 1 more Smart Citation
“…The diffraction peaks at 2θ = 7.59 and 8.72° reflect the (110) and (002) planes of UiO-66, where 2θ = 12.26, 14.97, 17.28, 22.42, 25.94, and 30.93° represent UiO- 66 (022), (113), (004), (115), (224), and (046) planes. This is consistent with the typical XRD pattern of UiO-66. , Compared to the XRD spectrum of UiO-66, the XRD spectra of Co-UiO-66 are not significantly different, suggesting that the coverage of the Co layer has little effect on the crystal structure of UiO-66.…”
Section: Resultssupporting
confidence: 84%
“…This is consistent with the typical XRD pattern of UiO-66. 30,31 Compared to the XRD spectrum of UiO-66, the XRD spectra of Co-UiO-66 are not significantly different, suggesting that the coverage of the Co layer has little effect on the crystal structure of UiO-66.…”
Section: Resultsmentioning
confidence: 98%
“…The device modifies polypeptide-doped PEDOT onto the electrode surface, which can detect CA15-3 in serum without being affected by biofouling and has high sensitivity and long-term stability. The linear range is 0.01~1000 U/mL, and the detection limit is 3.34 U/mL [ 86 ].…”
Section: Application Of Biosensor In Detection Of Tumor Biomarkersmentioning
confidence: 99%
“…Liver cancers are associated with elevated mortality rates across the world, [1][2][3] and while significant advancements have been made in surgical techniques, chemotherapy and other treatment approaches, the 5-year survival rate remains far from satisfactory. [4][5][6] Moreover, liver cancer is the most common type of cancer in China. Specifically, cancer recurrence at the intermediate or advanced stage occurs in approx.…”
Section: Introductionmentioning
confidence: 99%