2001
DOI: 10.1097/00006324-200104000-00013
|View full text |Cite
|
Sign up to set email alerts
|

A Review of Methods for Measuring Corneal Topography

Abstract: A review of some methods and their optical principles for measuring the corneal topography are presented in this paper. The concepts of principal curvatures and the ambiguity concerning the axial curvature of surfaces without symmetry of revolution are analyzed. These methods are divided into three groups according to the following optical principles: (1) specular reflection, which includes the Placido disk system, interferometry, and moiré deflectometry; (2) diffuse reflection, which includes moiré fringes, r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
47
0
2

Year Published

2010
2010
2024
2024

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 73 publications
(55 citation statements)
references
References 23 publications
0
47
0
2
Order By: Relevance
“…Los principios ópticos de algunos métodos que son implementados para medir la topografía de la córnea se pueden clasificar de acuerdo a los principios físicos usados en la medición [3], entre éstos se encuentran la reflexión especular, la reflexión difusa y luz dispersada. La técnica de reflexión especular considera la superficie anterior de la córnea como un espejo convexo, como en los sistemas basados en los discos de Plácido [4].…”
Section: Introductionunclassified
“…Los principios ópticos de algunos métodos que son implementados para medir la topografía de la córnea se pueden clasificar de acuerdo a los principios físicos usados en la medición [3], entre éstos se encuentran la reflexión especular, la reflexión difusa y luz dispersada. La técnica de reflexión especular considera la superficie anterior de la córnea como un espejo convexo, como en los sistemas basados en los discos de Plácido [4].…”
Section: Introductionunclassified
“…PDCT was the pioneer method in videokeratoscopes (4) , whereby a patient's cornea is illuminated by concentric rings, which create an image that is reflected by the anterior surface of the cornea. The reflected image is computer analyzed, and a curvature color map of the corneal surface is generated (4) .…”
mentioning
confidence: 99%
“…The reflected image is computer analyzed, and a curvature color map of the corneal surface is generated (4) . PDCT is established as a valid and reliable method of corneal evaluation, and its use has become part of routine clinical practice (1)(2)5) .…”
mentioning
confidence: 99%
See 2 more Smart Citations