2023
DOI: 10.1002/adem.202201034
|View full text |Cite
|
Sign up to set email alerts
|

A Review of X‐Ray Imaging at the BAMline(BESSY II)

Abstract: The hard X‐ray beamline BAMline at BESSY II (Berlin, Germany) has now been in service for 20 years. Several improvements have been implemented in this time, and this review provides an overview of the imaging methods available at the BAMline. Besides classic full‐field synchrotron X‐ray computed tomography (SXCT), also absorption edge CT, synchrotron X‐ray refraction radiography (SXRR), and synchrotron X‐ray refraction tomography (SXRCT) are used for imaging. Moreover, virtually any of those techniques are cur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1
1

Relationship

3
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 87 publications
0
8
0
Order By: Relevance
“…Both setups at BAMline [ 72 ] and P05 [ 73 ] are using a combination of a scintillator and a sCMOS camera as detectors. Table 5 summarizes the experimental parameters.…”
Section: Methodsmentioning
confidence: 99%
“…Both setups at BAMline [ 72 ] and P05 [ 73 ] are using a combination of a scintillator and a sCMOS camera as detectors. Table 5 summarizes the experimental parameters.…”
Section: Methodsmentioning
confidence: 99%
“…During image acquisition, the X-ray photons that reach the imaging receptor, e.g., the digital detector array (DDA) used in this study, are sensed by the pixels of the DDA and then are converted to gray values that can be digitally processed and visualized [39]. It is important to mention that the equation above, which follows the Lambert-Beer exponential law could only be realized with a monochromatic X-ray source, e.g., synchrotron [40]. With the polychromatic nature of the X-ray tube used more commonly for image acquisition in NDT radiography applications, the generated X-rays have different energy levels, and this affects the intensity distributions during image acquisition [41].…”
Section: How Exposure Factors Affect Image Qualitymentioning
confidence: 99%
“…During image acquisition, the X-ray photons that reach the imaging receptor, e.g., the digital detector array (DDA) used in this study, are sensed by the pixels of the DDA, and then are converted to grey values that can be digitally processed and visualized [38]. It is important to mention that the equation above which follows the Lambert-beer exponential law could only be realized with a monochromatic X-ray source, e.g., synchrotron [39]. With the polychromatic nature of X-ray tube used more commonly for image acquisition both in NDT radiography applications, the generated X-rays have different energy levels and this affects the intensity distributions during image acquisition [40].…”
Section: How Exposure Factors Affect Image Qualitymentioning
confidence: 99%