2023
DOI: 10.1177/15280837231175062
|View full text |Cite
|
Sign up to set email alerts
|

A review on the recent developments in design and integration of electromyography textile electrodes for biosignal monitoring

Bulcha Belay Etana,
Benny Malengier,
Kwa Timothy
et al.

Abstract: Due to recent developments in wearable sensor technology, textile electrodes are routinely being employed in electromyography (EMG) for continuous monitoring of the biosignals from the muscles. However, the performance of such smart textile-based health monitoring devices depends on several factors such as, the sensitivity (impedance), durability (reusable/washable), users' comfort ability, integrability, and automatability. In this article we review the characteristics and the performance of the EMG textile e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 127 publications
(186 reference statements)
0
1
0
Order By: Relevance
“…The main disadvantages of the gelled electrode are its fixed form (rigid circular form), drying of its gel on prolonged usage, lower wearability while performing sports or outdoor activities, and its disposal after a single use. In recent decades, dry electrodes have been proposed to replace wet electrodes on the grounds of their wearability (embedded into fabric and other accessories), reasonably good performance, and sustainability features (such as washability and reusability) [ 8 , 9 , 10 , 11 , 12 ]. Unlike the conventional Ag/AgCl gelled electrodes, the wearable dry electrodes can be designed in different shapes (circular, rectangular patch), and require minimal power for functioning.…”
Section: Introductionmentioning
confidence: 99%
“…The main disadvantages of the gelled electrode are its fixed form (rigid circular form), drying of its gel on prolonged usage, lower wearability while performing sports or outdoor activities, and its disposal after a single use. In recent decades, dry electrodes have been proposed to replace wet electrodes on the grounds of their wearability (embedded into fabric and other accessories), reasonably good performance, and sustainability features (such as washability and reusability) [ 8 , 9 , 10 , 11 , 12 ]. Unlike the conventional Ag/AgCl gelled electrodes, the wearable dry electrodes can be designed in different shapes (circular, rectangular patch), and require minimal power for functioning.…”
Section: Introductionmentioning
confidence: 99%