A review on the sizing and selection of control valves for thermal hydraulics for reactor system applications

Palash K. Bhowmik,
Jubair A. Shamim,
Piyush Sabharwall
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…It is similar to one used by Yang et al [30] as per the ASME PTC 25 standards. The components for the experimental system are marked as the supercritical boiler (1), steam separator (2), on-off valve (3), storage vessel (4), on-off valve (5), pressure measuring system (6), isolating valve (7), lift testing device (8), measured PRV (9), silencer (10), quick exhausting valve (11), testing vessel (12), and control valves (13)(14)(15)(16)(17). Saturated steam from a supercritical boiler is stored in a high-pressure vessel, and the PSV is attached to a test vessel.…”
Section: Psv In High-pressure Thermal-hydraulic Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…It is similar to one used by Yang et al [30] as per the ASME PTC 25 standards. The components for the experimental system are marked as the supercritical boiler (1), steam separator (2), on-off valve (3), storage vessel (4), on-off valve (5), pressure measuring system (6), isolating valve (7), lift testing device (8), measured PRV (9), silencer (10), quick exhausting valve (11), testing vessel (12), and control valves (13)(14)(15)(16)(17). Saturated steam from a supercritical boiler is stored in a high-pressure vessel, and the PSV is attached to a test vessel.…”
Section: Psv In High-pressure Thermal-hydraulic Experimentsmentioning
confidence: 99%
“…In order to maximize reliability, PSV/PRV designs should be as simple as possible [10]. In the event of an overpressure situation, the valve must open at a predetermined pressure, allow flow at a rated capacity, and then close when the system pressure has returned to an acceptable level [11,12]. Various process fluids-including air, water, and other potential corrosive media-must be compatible with PSVs/PRVs [13] A consistent, smooth, and stable operation is also required for various fluids and fluid phases [14].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation