Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
This paper presents the use of noncontact ultrasound for the nondestructive detection of defects in two plastic plates made of polyamide (PA6) and polyethylene (PE). The aim of the study was to: (1) assess the presence of defects as well as their size, type, and orientation based on the amplitudes of Lamb ultrasonic waves measured in plates made of polyamide (PA6) and polyethylene (PE) due to their homogeneous internal structure, which mainly determined the selection of such model materials for testing; and (2) verify the possibilities of building automatic quality control and defect detection systems based on ML based on the results of the above-mentioned studies within the Industry 4.0/5.0 paradigm. Tests were conducted on plates with generated synthetic defects resembling defects found in real materials such as delamination and cracking at the edge of the plate and a crack (discontinuity) in the center of the plate. Defect sizes ranged from 1 mm to 15 mm. Probes at 30 kHz were used to excite Lamb waves in the slab material. This method is sensitive to the slightest changes in material integrity. A significant decrease in signal amplitude was observed, even for defects of a few millimeters in length. In addition to traditional methods, machine learning (ML) was used for the analysis, allowing an initial assessment of the method’s potential for building cyber-physical systems and digital twins. By training ML models on ultrasonic data, algorithms can distinguish subtle differences between signals reflected from normal and defective areas of the material. Defect types such as voids, cracks, or weak bonds often produce distinct acoustic signatures, which ML models can learn to recognize with high accuracy. Using techniques like feature extraction, ML can process these high-dimensional ultrasonic datasets, identifying patterns that human inspectors might overlook. Furthermore, ML models are adaptable, allowing the same trained algorithms to work on various material batches or panel types with minimal retraining. This combination of automation and precision significantly enhances the reliability and efficiency of quality control in industrial manufacturing settings. The achieved accuracy results, 0.9431 in classification and 0.9721 in prediction, are comparable to or better than the AI-based quality control results in other noninvasive methods of flat surface defect detection, and in the presented ultrasonic method, they are the first described in this way. This approach demonstrates the novelty and contribution of artificial intelligence (AI) methods and tools, significantly extending and automating existing applications of traditional methods. The susceptibility to augmentation by AI/ML may represent an important new property of traditional methods crucial to assessing their suitability for future Industry 4.0/5.0 applications.
This paper presents the use of noncontact ultrasound for the nondestructive detection of defects in two plastic plates made of polyamide (PA6) and polyethylene (PE). The aim of the study was to: (1) assess the presence of defects as well as their size, type, and orientation based on the amplitudes of Lamb ultrasonic waves measured in plates made of polyamide (PA6) and polyethylene (PE) due to their homogeneous internal structure, which mainly determined the selection of such model materials for testing; and (2) verify the possibilities of building automatic quality control and defect detection systems based on ML based on the results of the above-mentioned studies within the Industry 4.0/5.0 paradigm. Tests were conducted on plates with generated synthetic defects resembling defects found in real materials such as delamination and cracking at the edge of the plate and a crack (discontinuity) in the center of the plate. Defect sizes ranged from 1 mm to 15 mm. Probes at 30 kHz were used to excite Lamb waves in the slab material. This method is sensitive to the slightest changes in material integrity. A significant decrease in signal amplitude was observed, even for defects of a few millimeters in length. In addition to traditional methods, machine learning (ML) was used for the analysis, allowing an initial assessment of the method’s potential for building cyber-physical systems and digital twins. By training ML models on ultrasonic data, algorithms can distinguish subtle differences between signals reflected from normal and defective areas of the material. Defect types such as voids, cracks, or weak bonds often produce distinct acoustic signatures, which ML models can learn to recognize with high accuracy. Using techniques like feature extraction, ML can process these high-dimensional ultrasonic datasets, identifying patterns that human inspectors might overlook. Furthermore, ML models are adaptable, allowing the same trained algorithms to work on various material batches or panel types with minimal retraining. This combination of automation and precision significantly enhances the reliability and efficiency of quality control in industrial manufacturing settings. The achieved accuracy results, 0.9431 in classification and 0.9721 in prediction, are comparable to or better than the AI-based quality control results in other noninvasive methods of flat surface defect detection, and in the presented ultrasonic method, they are the first described in this way. This approach demonstrates the novelty and contribution of artificial intelligence (AI) methods and tools, significantly extending and automating existing applications of traditional methods. The susceptibility to augmentation by AI/ML may represent an important new property of traditional methods crucial to assessing their suitability for future Industry 4.0/5.0 applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.