2022
DOI: 10.1016/j.conengprac.2022.105104
|View full text |Cite
|
Sign up to set email alerts
|

A Robust Adaptive Super-Twisting Sliding Mode Controller applied on grid-tied power converter with an LCL filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
37
0
2

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 43 publications
(39 citation statements)
references
References 37 publications
0
37
0
2
Order By: Relevance
“…It is important to remark that uDR$$ {u}_{DR} $$ is not considered in the stability analysis, since the grid dynamics is rejected by estimation on point of common coupling voltages, considering its characteristics, which is periodic and stable, as made in References 56,57,63,64.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…It is important to remark that uDR$$ {u}_{DR} $$ is not considered in the stability analysis, since the grid dynamics is rejected by estimation on point of common coupling voltages, considering its characteristics, which is periodic and stable, as made in References 56,57,63,64.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…The simplification method is based on Reference 60, where the capacitor dynamics is neglected during controller design. This procedure was also used in References 56,57,62,65,66, aiming to reduce the quantity of parameters to design in their adaptive controllers, which depends on relative degree of chosen reference model that must be the same relative degree of the nominal part of the plant. Different from all these control strategies, the hybrid robust MRAC‐PI controller does not require a reference model, even being a direct adaptive controller, because it can track the reference signal straightforwardly.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, it is not explicitly modeled, as it can vary significantly depending on the specific conditions and characteristics of the local grid. 26 For current regulation of the grid-tied VSI with LCL filter, it is necessary to ensure that the measured currents are in phase with the grid voltage, maintaining the power flow from the DC bus to the grid (injection into the grid). Furthermore, voltage and current measurements are firstly read in abc coordinates and subsequently converted to 𝛼𝛽 coordinates by means of Clarke transformation.…”
Section: Vsi Model and Designmentioning
confidence: 99%
“…Similarly, in ref. [16], a discrete‐time adaptive super‐twisting sliding mode controller is designed for the closed‐loop control of LCL‐type grid‐connected inverters. Regrettably, the modelling in this study oversimplifies the system by disregarding the capacitance fluctuation in the LCL coupling network.…”
Section: Introductionmentioning
confidence: 99%