2019
DOI: 10.3390/s19204455
|View full text |Cite
|
Sign up to set email alerts
|

A Role-Based Access Control Model in Modbus SCADA Systems. A Centralized Model Approach

Abstract: Industrial Control Systems (ICS) and Supervisory Control systems and Data Acquisition (SCADA) networks implement industrial communication protocols to enable their operations. Modbus is an application protocol that allows communication between millions of automation devices. Unfortunately, Modbus lacks basic security mechanisms, and this leads to multiple vulnerabilities, due to both design and implementation. This issue enables certain types of attacks, for example, man in the middle attacks, eavesdropping at… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 40 publications
(27 citation statements)
references
References 25 publications
1
26
0
Order By: Relevance
“…As examples, in the following sections, we have considered the general context information [6], the relationship context information [20] and the situational context information [10], the dynamic contextual role information [8], and the fuzzy context information [7]. Recently, a new secure version of an RBAC approach has also been introduced [70].…”
Section: The Rbac Approaches With Spatial and Temporal Contextsmentioning
confidence: 99%
“…As examples, in the following sections, we have considered the general context information [6], the relationship context information [20] and the situational context information [10], the dynamic contextual role information [8], and the fuzzy context information [7]. Recently, a new secure version of an RBAC approach has also been introduced [70].…”
Section: The Rbac Approaches With Spatial and Temporal Contextsmentioning
confidence: 99%
“…In [ 5 ], entitled “A Role-Based Access Control Model in Modbus SCADA Systems. A Centralized Model Approach”, by Figueroa-Lorenzo et al, the security problems of the Modbus protocol which is widely used in Industrial Control Systems (ICS) and Supervisory Control systems and Data Acquisition (SCADA) networks is addressed.…”
Section: Contributionsmentioning
confidence: 99%
“…Modbus TCP/IP is mostly used in the data sharing between the field device level (e.g., PLC, CAN J1939 to the Modbus Gateway) and the SCADA system level. Modbus TCP/IP as a protocol could support communication between field devices via TCP, i.e., between sensors, actuators and PLCs [ 39 , 40 ].…”
Section: System Architecture Designmentioning
confidence: 99%