2014
DOI: 10.1039/c4an00227j
|View full text |Cite
|
Sign up to set email alerts
|

A sample-effective calibration design for multiple components

Abstract: The experimental design of mixtures for multivariate calibration is introduced. The idea of this design is based on uniform distribution of experimental points in a concentration hypercube. Unlike the already reported uniform designs this one is pretty simple and not computationally demanding. The suggested approach does not employ the concept of fixed "levels" and allows for designs with any number of experimental mixtures and any number of components depending on "time and money" considerations for each part… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 27 publications
(15 citation statements)
references
References 14 publications
0
14
0
1
Order By: Relevance
“…Aqueous solutions containing mixtures of six lanthanides (Ce, Pr, Nd, Sm, Eu, Gd) in concentration range 10 −6 –10 <M‐3 mol/L were analyzed. Mixture compositions were designed using the approach suggested in . pH values of all mixtures were fixed at 2 by nitric acid addition in order to avoid metal hydrolysis.…”
Section: Methodsmentioning
confidence: 99%
“…Aqueous solutions containing mixtures of six lanthanides (Ce, Pr, Nd, Sm, Eu, Gd) in concentration range 10 −6 –10 <M‐3 mol/L were analyzed. Mixture compositions were designed using the approach suggested in . pH values of all mixtures were fixed at 2 by nitric acid addition in order to avoid metal hydrolysis.…”
Section: Methodsmentioning
confidence: 99%
“…For each data point, the microfluidic device was (i) fully flushed with twice its internal volume, in order to assure reaching a steady state; (ii) further flushed until 600 mL of each phase was retrieved in collecting output vials, for off-line XRF or ICP-OES analysis (see the ESI † for more details about the XRF analysis). 32,38,39 The necessary overall time required to obtain each sample varies according to the flow rate used (always equal, by construction, for both phases (Fig. 1)) which in our case varies from 34 mL min À1 to 0.57 mL min À1 (see Table S2 of the ESI †).…”
Section: Microfluidic Systemmentioning
confidence: 98%
“…Compositions of these mixtures are given in Table 1. Although there are special calibration designs for the two component mixtures described in literature [23,24], in this case we had to deal with the limited number of fixed concentration levels to meet safety requirements of Pu 4+ solutions handling and to minimize the waste amount.…”
Section: Samplesmentioning
confidence: 99%